Object 1011h: restore parameters, Object 1012h: cob-id time stamp object, Object 1013h: high resolution time stamp – BEI Sensors THK4 User Manual
Page 23

www.beisensors.com
page
23/57
Object 1011h: Restore Parameters
This object is used to restore device and CANopen related parameters to factory settings.
Subindex Description
Data Type
Default Value
Access
Restore after
BootUp
0
Number of sub indices
Unsigned 8
2
ro
no
1
Restore all parameters
Unsigned 32
“load”
rw
no
Storing procedure
To save the parameters to non volatile memory the access signature “load” has to be sent to the
corresponding subindex of the device.
Most significant word Least significant word
ASCII D a
o
l
Hex value 64h
61h
6Fh
6Ch
Note: The restoration of parameters will only be taken into account after a power up or reset command.
Please check all parameters before you store them to the non volatile memory.
Object 1012h: COB-ID Time Stamp Object
This object contains the COB-ID of the Time Stamp object.
Subindex Description
Data Type
Default Value
Access
Restore after
BootUp
0 -
Unsigned
32
100h
rw
no
Object 1013h: High Resolution Time Stamp
This object contains a time stamp with a resolution of 1µs.
Subindex Description
Data Type
Default Value
Access
Restore after
BootUp
0 -
Unsigned
32
0
rw
no