Bell & Gossett S14367B Technologic Constant Speed Pump Controller User Manual
Page 30

Technologic
®
Constant Speed Pump Controller Installation, Operation and Maintenance Manual
30
5.1
Battery
The system memory, including all user setup data, is
buffered by a 3V lithium battery while the unit is off.
When the controller begins to detect low voltage on
the battery, it will display an alarm to give the user
adequate time to replace it. If the battery is not
replaced, the user setup data may be lost when the
unit is powered down.
5.2
Signal Generator (analyzer) -
recommended
The following signal generators are recommended:
Beta calibrator Model 434 20mA signal analyzer,
Altek calibrator Model 334 4-20mA loop analyzer or
Druck USP III loop calibrator. The instruments may
be purchased from a Local Process Control
Distributor. If some other instrument is used it must
float above ground, and preferably be battery pow-
ered.
5.3
Field Repair
Typical field repairs include replacing fuses, replacing
input/output modules, and assuring connections are
correct and secure. See Table 42 for a list of spare
parts.
DANGER:
Troubleshooting live control
panels exposes personnel to hazardous
voltages. Electrical troubleshooting must only be
done by a qualified electrician. FAILURE TO
FOLLOW THESE INSTRUCTIONS WILL
RESULT IN SERIOUS PERSONAL INJURY,
DEATH, AND/OR PROPERTY DAMAGE.
Description
ITT Part Number
Operator Interface Panel
S14368
Relay and power monitor rack
S14369
CT (40 Amp)
S14370
CT (150 Amp)
S14371
CT (400 Amp)
S14372
AI984
S14373
EX270
S13268
DO722
S12572
Lithium Battery
S12327
Power Supply (1 amp)
BP0140
Low Suction Pressure Switch
S76833
NEMA 1 (10-100psi)
Low Suction Pressure Switch
BP0223
NEMA 4 (0-100psi)
Description
ITT Part Number
Low Level Relay
176309
Low Level Plug-In Module Socket 211161
Probes for indoor use
176203
Probes for outdoor use
179524
DP Switch
S12221
Pressure Transducer (0-100PSI)
S13203
Pressure Transducer (0-300PSI)
S13204
RTD
S13205
Flow Switch (NEMA 1)
120611
Flow Switch (NEMA 4)
120610
Horn
S76699
Pilot Light (Red)
DE1793
Thermal Relief Valve
S51260
Table 42: Spare Parts
5.4
Program Updating
To update to a new version of software, the program
must be uploaded through the RS232 port on the
controller using a laptop. Consult the factory for any
updates.
5.5
Info Screens
Path: Status Screens / Info (8)
←
INFO
→
Job#:QM1234 Ver:1.0
Volts:460
App:70E
Comms:None
3Φ:$
←
INFO
→
Suc Pr:###
CT:40
Sys Pr:###
G:####
# Pumps:# # # O:####
←
INFO
→
HP1:###.# HP4:###.#
HP2:###.# HP5:###.#
HP3:###.# HP6:###.#
The Info screens contain all of the parameters that
have been factory set. See Table 43 for a description
of the variables.
Section 5 — Maintenance