Record level calibration, Record eq calibration – Universal Audio UAD POWERED PLUG-INS ver.6.1 User Manual
Page 169
UAD Powered Plug-Ins Manual
- 169 -
Chapter 12: Ampex ATR-102
11. Increase
(clockwise) until the meter level is reduced by –3.5 dB from
its maximum (for 3.5 dB of overbias; see
).*
*When calibrating at 3.75 or 7.5 IPS, the tone generator is at a lower level, therefore meter resolu-
tion is decreased. To increase meter precision when adjusting bias at the lower tape speeds, con-
sider temporarily increasing the reproduce level.
Record Level
Calibration
12. Set the
frequency to 1 kHz.
below
(the level depends on tape speed).
Record EQ
Calibration
pends on tape speed).
) so the
above (the level depends on tape
speed).
Note:
If HF EQ is adjusted by a large amount, it may be necessary to reca-
librate the record level (steps 12, 13).
The manual calibration procedure is complete.
For related information, see the
Table 11. Meter Levels for Record and HF EQ Adjustments
Tape Speed
Meter Level
3.75 IPS
–20 dB
7.5 IPS
–10 dB
15 IPS
0 dB
30 IPS
0 dB
Table 12. Record HF EQ Calibration Frequencies and Levels
Tape Speed
Tone Frequency
Tone Level
3.75 IPS
5 kHz*
–16 dB
7.5 IPS
10 kHz
–6 dB
15 IPS
15 kHz
+4 dB
30 IPS
20 kHz
+4 dB
*Note: 7.5 kHz is specified in Ampex manual.