Chapter 2

– 20 –

PCI-1710 series User’s Manual

Advantech Co., Ltd.
www.advantech.com

Testing Analog Input Function

Click the Analog Input tab to bring it up to the front of the screen.
Select the input range for each channel in the Input range drop-down
boxes. Configure the sampling rate on the scroll bar. Switch the
channels by using the up/down arrow.

Figure 2-10: Analog Input tab on the Device Test dialog box

Testing Analog Output Function (only for PCI-1710/1710HG/

1711/1716)

Click the Analog Output tab to bring it up to the foreground. The
Analog Output tab allows you to output quasi-sine, triangle, or square
waveforms generated by the software automatically, or output single
values manually. You can also configure the waveform frequency and
output voltage range.

Figure 2-11: Analog Output tab on the Device Test dialog box