Thermal Protection and Considerations

The internal LDOs and drivers can generate more power
than the package for the device can safely dissipate.
Ensure that the driver LDO loading is less than the pack-
age can dissipate. Total power dissipation for the device
is calculated using the following equation:

P

TOTAL

= P

C/Q

+ P

DO

+ P

5

+ P

LDO33

+ P

Q

+

P

CLCQ

+ P

CLDI

where P

C/Q

is the power generated in the C/Q driver,

P

DO

is the power dissipated by the DO driver, P

5

and

P

LDO33

are the power generated by the LDOs, P

Q

is the

quiescent power generated by the device, and P

CLCQ

and P

CLDI

are the power generated in the C/Q and DI

current sinks.
Ensure that the total power dissipation is less than the
limits listed in the

Absolute Maximum Ratings

section.

Use the following to calculate the power dissipation (in
mW) due to the C/Q driver:

P

C/Q

= [I

C/Q

(max)]

Ч [0.5 + 7 Ч I

C/Q

(max)]

Calculate the internal power dissipation of the DO driver
using the following equation:

P

DO

= [I

DO

(max)]

Ч [0.5 + 7 Ч I

DO

(max)]

Calculate the power dissipation in the 5V LDO, V5, using

the following equation:

P

5

= (V

LDOIN

- V

5

)

× I

5

where I

5

includes the I

LDO33

current sourced from

LDO33.
Calculate the power dissipated in the 3.3V LDO, LDO33,
using the following equation:

P

LDO33

= 1.7V

× I

LDO33

Calculate the quiescent power dissipation in the device
using the following equation:

P

Q

= 5mA

× V

CC

(max)

If the current sinks are enabled, calculate their associ-
ated power dissipation as:

P

CLCQ

= 7mA

× V

C/Q

(max)

P

CLDI

= 7mA

× V

DI

(max)

Overtemperature Warning

Bits in the Status and Mode registers are set when the
temperature of the device exceeds +115NC (typ). The
OTempInt bit in the Status register is set and IRQ asserts
when the OTemp bit in the Mode register is set. Read the
Status register to clear the OTempInt bit and IRQ.
The OTemp bit is cleared when the die temperature falls
to +95NC.
The device continues to operate normally unless the
die temperature reaches the +150NC thermal shutdown
threshold, when the device enters thermal shutdown.

Thermal Shutdown

All regulators and the C/Q and DO output drivers are
automatically switched off when the internal die tempera-
ture exceeds the +150NC (typ) thermal shutdown thresh-
old. SPI communication is not available during a thermal
shutdown event.
Regulators are automatically switched on when the inter-
nal die temperature falls below the thermal shutdown
threshold plus hysteresis. The internal registers return to
their default state when the V