7
Only connect the battery after all other connections have been made.
Connection
The (+) RED wire connects to the positive contact of the battery and the (-) BLACK wire connects to 
the negative contact of the battery. The battery is protected by a 3A resettable fuse, and it is 
charged by a current limiting regulated voltage source in the system. 
Periodic test 
The system performs a back-up battery test automatically once every 24 hours. The test takes from 
5 seconds to 2 minutes depending on the condition of the battery. 
When the battery condition is normal, 2 beeps will be produced. When a faulty condition is detected, 
first 5 beeps will sound, followed by one beet every 30 seconds. The LED battery on the digital 
keypad will be lit. 
Manual test 
The battery test can be manually initiated via a key switch (not applicable for 
HAM263D) or the
keypad. Refer to the keypad operations chapter for more details. The manually initiated battery test 
initiates the start of a new 24 hour period 
Note: 
Battery test will not start or continue when an alarm condition exists or occurs, or when AC power 
failure is detected. 
2.3
Power supply
The power supply for the HAM263D is a general purpose AC power adaptor that provides 16,5V AC, 
with a maximum output current of 3.000mA. It is designed for indoor use only. 
Only connect the power plug to the mains outlet after all other connections have 
been made. 
•
Use the mounting holes (2) to mount the adaptor in a dry location, close to a mains outlet and to 
the master control unit. 
•
Make sure that power consumption of the connected system does not exceed the specifications of 
the power adaptor. 
•
Connect the 16,5VAC output voltage to contacts 1 and 2 of the master control unit.
•
Do not insert the power plug (1) in the mains before all necessary connections have been made 
and the whole alarm system is connected. 
•
specifications
Input voltage
230VAC, 50Hz
Output voltage
16,5VAC
Output current
3.000mA Max.
Rated power
49,5VA
Protection
Built-in thermal fuse and current fuse
Dimensions
76 x 92 x 62mm
Weight
±1.250g
Power plug
CEE 7/16 (Europlug 2.5 A/250 V unearthed)
3.
Sensors
Different types of sensor devices can be connected to the input relais, e.g. PIR sensor (HAA52N), 
panic button (HAA60), magnetic contacts etc.... 
1. Power plug
2. Mounting hole 
3. Power indicator 
4. Power output, 16,5VAC 