Connection block

1
2

AC in

AC Power input from a 16.5VAC, minimum 1.5A, 50~60Hz transformer. The primary
side of the transformer must be connected to an un-switched receptacle.
The used transformer must comply with the EN61558 standard for European
countries.

3

DC out

Un-switched +12VDC output power referring to the common ground. Continues
output, not depending on the arm/disarmed status. Can be used for devices requiring
uninterrupted power supply e.g. smoke detectors, control keypads etc. This output
has a 750mA resettable fuse.

4

GND

Common Ground (-)

5

DC out

Continuous +12VDC output power under normal condition (no alarm). The output is
switched OFF at alarm condition; it has a 2.5A resettable fuse. Suitable for the
connection of satellite siren/strobe light with internal battery.

6 DC out

Continuous +12V output power under alarm condition until the system is disarmed.
The output has a 2.5A resettable fuse. It is mostly suitable for providing power for the
stand alone strobe light or those devices require continuous operation at alarm
condition after the siren timer is reset (e.g. SV/PSL3).

7 DC out

+12V output power under alarm condition with the duration depending on the
setting of the alarm timer; it has a 2.5A resettable fuse. Can be used for electronic
siren or alarm bell.

The following 4 contacts are dedicated for the connection of one or more

digital keypads, e.g.

HAA263D, HAA85WP… The total number of keypad(s) and key switches however is limited to four.

8 GND

Common Ground (-) for keypad(s)

9 CLK

Clock wire

for keypad(s)

10 Data

Data wire

for keypad(s)

11 DC out

+12V output power common point with a 750mA resettable fuse for keypad(s) and
key switches.

The following 5 contacts are for inputs from key switches, e.g. HAA80MK.

12 Part 1 ON/OFF Arm/disarm partition 1: accepts normally open (N.O) momentary switches.

Multiple switches can be connected in parallel.

13 Part 2 ON/OFF Arm/disarm partition 1: accepts normally open (N.O) momentary switches.

Multiple switches can be connected in parallel.

14 Part 1 status

LED indication partition 1: show zone status of partition 1.

15 Part 2 status

LED indication partition 2: show zone status of partition 2.

16 System status

LED indication system: show zone status of entire system.

Note that contacts 12 and 13 can be connected together to one key switch to arm or disarm
partition one and two simultaneously.