If you have forgotten the master code, you can reset it. See b. Reset master code.



The master code is the authorization code for setting the system in programming mode.

It can consist of 4 to 6 digits.

After entering a new master code, the old one is erased.

Format:

01yyyyyy#
01

master code

yyyyyy = 4 to 6 digits
# =

validation


e.

Record a user code

Notes: user code

-

Any user code must be different from the master code.

-

It is recommended to program a different code for every user.

It can consist of 4 to 6 digits.

After entering a new user code, the old one is replaced.

To remove a user code, key in the location, immediately followed by #.

Format:

XXyyyyyy#
XX =

11

USER CODE 1 for arm/disarm control of part. 1

12

USER CODE 2 for arm/disarm control of part. 2

13

USER CODE 3 for arm/disarm control of the
whole system (partition 1 and 2)

yyyyyy =

4 to 6 digits

# =

validation

f.

Memorize frequently bypassed zones (“HOME” mode)

HOME mode is only available for use with USER CODE 3 (whole system). However, partitions
can be bypassed by bypassing the zones within the partition one by one.

Zone 8 (24 hour zone) is excluded from use in HOME mode

Format:

HOMEyyyyyy#
HOME

Press HOME button on keypad

yyyyyy =

List of zones to be enabled, sequential e.g. 245 to
bypass zones 2, 4 and 5

# =

validation

To use the home mode, simply type USER CODE 3,

and

; all programmed zones will

automatically be bypassed.

g.

Keypad audible notification set-up

Some audible notification can be passed on to the keypad. This is the case for the exit and entry
delay, after an alarm condition and for each key button press.

Alarm conditions concerning battery low or AC power failure conditions are always ON.

Passing these notifications through to the keypad will not affect the beep settings on the master
control unit.

Note that confirmation beeps from the

-button and

-button are always enabled.

14yyyy#
14

master code

yyyy =

4 digits: 0=beep disabled, 1=beep enabled (default)

digit 1 Beep for exit delay

digit 2 Beep for entry delay

digit 3 Beep after alarm condition

digit 4 Beep after each key button press

# =

validation