Velleman HAM263D User Manual
Page 15

HAM263D
03 (15/11/2013)
VELLEMAN
15
-
If you have forgotten the master code, you can reset it. See b. Reset master code.
•
The master code is the authorization code for setting the system in programming mode.
•
It can consist of 4 to 6 digits.
•
After entering a new master code, the old one is erased.
•
Format:
01yyyyyy#
01
master code
yyyyyy = 4 to 6 digits
# =
validation
e.
Record a user code
Notes: user code
-
Any user code must be different from the master code.
-
It is recommended to program a different code for every user.
•
It can consist of 4 to 6 digits.
•
After entering a new user code, the old one is replaced.
•
To remove a user code, key in the location, immediately followed by #.
•
Format:
XXyyyyyy#
XX =
11
USER CODE 1 for arm/disarm control of part. 1
12
USER CODE 2 for arm/disarm control of part. 2
13
USER CODE 3 for arm/disarm control of the
whole system (partition 1 and 2)
yyyyyy =
4 to 6 digits
# =
validation
f.
Memorize frequently bypassed zones (“HOME” mode)
•
HOME mode is only available for use with USER CODE 3 (whole system). However, partitions
can be bypassed by bypassing the zones within the partition one by one.
•
Zone 8 (24 hour zone) is excluded from use in HOME mode
•
Format:
HOMEyyyyyy#
HOME
Press HOME button on keypad
yyyyyy =
List of zones to be enabled, sequential e.g. 245 to
bypass zones 2, 4 and 5
# =
validation
•
To use the home mode, simply type USER CODE 3,
and
; all programmed zones will
automatically be bypassed.
g.
Keypad audible notification set-up
•
Some audible notification can be passed on to the keypad. This is the case for the exit and entry
delay, after an alarm condition and for each key button press.
•
Alarm conditions concerning battery low or AC power failure conditions are always ON.
•
Passing these notifications through to the keypad will not affect the beep settings on the master
control unit.
•
Note that confirmation beeps from the
-button and
-button are always enabled.
14yyyy#
14
master code
yyyy =
4 digits: 0=beep disabled, 1=beep enabled (default)
digit 1 Beep for exit delay
digit 2 Beep for entry delay
digit 3 Beep after alarm condition
digit 4 Beep after each key button press
# =
validation