Power divider overhaul, Remove power divider from differential carrier – Spicer Tandem Drive Axle Dual Range & Double Planetary 34,000-45,000 lbs User Manual
Page 34
Power Divider Overhaul
Remove Power Divider from Differential Carrier
(with carrier removed from axle housing)
NOTE: It is assumed that the differential carrier and
power divider assembly
have been removed from axle housing (see page 30) prior to starting
the following procedures:
1.
Mount differential carrier in
repair stand. Loosen input shaft
nut.
2.
Remove power divider cover
cap screws and lockwashers.
CAUTION:
DURING REMOVAL
OF POWER DIVIDER, THE
INTER-AXLE DIFFERENTIAL
MAY FALL OFF INPUT SHAFT
FROM DIFFERENTIAL CARRIER.
EXERT CAUTION TO PREVENT
DAMAGE OR INJURY.
3.
Attach chain hoist to input yoke
and lift power divider off carrier. If
power divider does not separate
easily, strike the cover near the
dowel pin locations with a mallet
(see illustration).
NOTE:
Lifting mechanism may
create nicks or burrs on input
yoke. Remove if present.
Power Divider Cover
Dowel Pin Location.
Pump model illustrated
4. Inter-axle Differential.
Lift dif-
ferential assembly off output shaft
side gear.
5. Output Shaft.
Tilt carrier and
remove the output shaft assembly.
6.
Output Shaft Side Gear Bearing
Cup.
If replacement is necessary,
use puller to remove bearing cup
from carrier.
NOTE:
Late Model Axles may be equipped with a Spring and Thrust Button mounted between input and
output shafts (see Service Bulletin at back of this manual).
NOTE:
For instructions on removing axle housing cover and output shaft rear bearing parts, see page 30.
34