background image

7000 Series Indicators EN-47

-Off-

*

0.002

kg

*

NET

0.000

kg

*

NET

-1.000

kg

PT

*

NET

0.000

kg

*

1.000

kg

*

0

0.000

kg

*

1.000

kg

*

0

0.000

kg

*

0

0.000

lb

*

0

0.000

kg

05:20 P

4.

OPERATION

4.1

Turning Indicator On/Off

To turn the indicator on, press ON/ZERO Off. The indicator performs a display test followed by a
series of informational displays, and then enters the last active mode.


To turn the indicator off, press and hold ON/ZERO Off until -OFF- appears.


If powered by AC mains, the indicator enters standby and displays the clock.


If powered by batteries, the indicator turns off completely.


4.2

Zero Operation

Press ON/ZERO Off to zero the display.

NOTE: The display must be stable and within the Zero Range.


4.3

Manual Tare

Place the container on the scale and press TARE.

NOTE: The display must be stable.

To clear the tare, remove all weight from the scale and press TARE.

4.4

Preset Tare

Enter the preset tare value using the numeric keypad, then press TARE. The display will show the PT
symbol and the tare value as a negative number.

To clear the preset tare, remove all weight from the scale and press TARE.

NOTE: The preset tare value may also be entered or cleared using the xT command. (See Section 5.1.)

4.5

Auto Tare

When Auto Tare is set ON in the Setup menu, the initial item placed on the scale is automatically
tared.

The tare value is automatically cleared when the weight on the scale is fully removed.


4.6

Changing Units of Measure

Press and hold Units until the desired unit of measure is displayed, then release the button.