beautypg.com

Comm 1, Baud, Parity – Ohaus DEFENDER 7000 BENCH SCALES Manual en User Manual

Page 41: Stop, Handsh, Mmenu, Comm1, Reset

background image

7000 Series Indicators EN-39

19200

9600

4800

2400

1200

COmM 1

BAUD

600

bAUd

300

8 NONE

7 NONE

COmM 1

PARITY

7 ODD

PArItY

7 EVEN

COmM 1

STOP BITS

2

StOP

1

HARDWARE

COmM 1

HANDSHAKE

XON-XOFF

HANdSH

NONE

mMENU

COM1

COmM1

RESET

YES

rESEt

NO

3.10 COM1, COM2 Menus

Enter this menu to define communication parameters.

NOTE: The COM2 menu is only available if an optional RS232 PC Board or RS485/RS422 PC Board
is installed.

3.10.1 Reset
Reset the COM menus to the factory defaults. Factory default settings are shown in bold.

NO

= not reset

YES

= reset




3.10.2 Baud
Set the baud rate.

300

= 300 bps

600

= 600 bps

1200

= 1200 bps

2400

= 2400 bps

4800

= 4800 bps

9600

= 9600 bps

19200

= 19200 bps







3.10.3 Parity
Set the data bits and parity.

7 EVEN

= 7 data bits, even parity

7 ODD

= 7 data bits, odd parity

7 NONE

= 7 data bits, no parity

8 NONE

= 8 data bits, no parity






3.10.4 Stop Bit
Set the number of stop bits.

1

= 1 stop bit

2

= 2 stop bits





3.10.5 Handshake
Set the flow control method.

NONE

= no handshaking

XON-XOFF

= XON/XOFF handshaking

HARDWARE

= hardware handshaking (COM1 menu only)