Comm 1, Baud, Parity – Ohaus DEFENDER 7000 BENCH SCALES Manual en User Manual
Page 41: Stop, Handsh, Mmenu, Comm1, Reset

7000 Series Indicators EN-39
19200
9600
4800
2400
1200
COmM 1
BAUD
600
bAUd
300
8 NONE
7 NONE
COmM 1
PARITY
7 ODD
PArItY
7 EVEN
COmM 1
STOP BITS
2
StOP
1
HARDWARE
COmM 1
HANDSHAKE
XON-XOFF
HANdSH
NONE
mMENU
COM1
COmM1
RESET
YES
rESEt
NO
3.10 COM1, COM2 Menus
Enter this menu to define communication parameters.
NOTE: The COM2 menu is only available if an optional RS232 PC Board or RS485/RS422 PC Board
is installed.
3.10.1 Reset
Reset the COM menus to the factory defaults. Factory default settings are shown in bold.
NO
= not reset
YES
= reset
3.10.2 Baud
Set the baud rate.
300
= 300 bps
600
= 600 bps
1200
= 1200 bps
2400
= 2400 bps
4800
= 4800 bps
9600
= 9600 bps
19200
= 19200 bps
3.10.3 Parity
Set the data bits and parity.
7 EVEN
= 7 data bits, even parity
7 ODD
= 7 data bits, odd parity
7 NONE
= 7 data bits, no parity
8 NONE
= 8 data bits, no parity
3.10.4 Stop Bit
Set the number of stop bits.
1
= 1 stop bit
2
= 2 stop bits
3.10.5 Handshake
Set the flow control method.
NONE
= no handshaking
XON-XOFF
= XON/XOFF handshaking
HARDWARE
= hardware handshaking (COM1 menu only)