7000 Series Indicators EN-35

ON

ON

ON

Scale Number
Set the status.

OFF

= the Scale Number line is not printed.

ON

= the Scale Number line is printed.


Scale No: X

Difference
Set the status.

OFF

= the difference is not printed following the Calibration Test procedure.

ON

= the difference is printed following the Calibration Test procedure.

--------- Cal Test ---------
New Cal: 10.000 kg
Old Cal: 9.999 kg
Diff: 0.001 kg
Wt. ID:------------------
------------ End -----------

Information
Set the status.

OFF

= the reference information is not printed.

ON

= the reference information is printed.

NOTE: The reference information is dependent on the mode and the ACCUMULATE setting.
Examples are shown below.

Mode

Accumulate set OFF

Accumulate set ON

Weighing

None

N: 10
Total: 10.000 kg
Avg: 1.000 kg
Std: 0.001 kg
Min: 0.999 kg
Max: 1.001 kg
Diff: 0.002 kg

Counting

APW: 0.100 kg

APW: 0.100 kg
N: 10
Total: 1000 Pcs
Avg: 100 Pcs
Std: 1 Pcs
Min: 99 Pcs
Max: 101 Pcs
Diff: 2 Pcs

Percent

Ref Wt: 1.23 kg

Ref Wt: 1.23 kg

Check Weighing

Under: 0.995 kg
Over: 1.005 kg

Under: 0.995 kg
Over: 1.005 kg
N: 10
Total: 10.000 kg
Avg: 1.000 kg
Std: 0.001 kg
Min: 0.999 kg
Max: 1.001 kg
Diff: 0.002 kg

Dynamic

Level: 0

Level: 0
N: 10
Total: 10.000 kg
Avg: 1.000 kg
Std: 0.001 kg

dIFF

OFF

CONtNt

DIFFERENCE

INFO

OFF

CONtNt

INFORMATION

SCAL.NO

OFF

CONtNt

SCALE NO