Operation

Setup Menu : Misc

3.10.3.6.18 Mag Current Rating Lock

This picklist value specifies whether the Magnet Current Rating

value (under the Load submenu) is locked or unlocked. The default

value is Unlocked.

3.10.3.6.19 PSwitch Settings Lock

This picklist value specifies whether persistent switch settings are

locked or unlocked. Persistent switch settings protected by this

setting (all under the Load submenu) are: the PSwitch Installed

picklist value, PSwitch Current Detect, the PSwitch Current value,

the PSwitch Heated Time value, the PSwitch Cooled Time value,

the PSwitch P/S Ramp Rate value, and the PSwitch P/S Cooling

Gain value. The default value is Unlocked.

3.10.3.6.20 Quench Detect Lock

This picklist value specifies whether the Enable Quench Detect

picklist value (under the Load submenu) is locked or unlocked. The

default value is Unlocked.

3.10.3.6.21 Quench Rate Lock

This picklist value specifies whether the Quench Rate picklist value

(under the Misc submenu) is locked or unlocked. The default value

is Unlocked.

+0.00 A — Mag Current Rating Lock
+0.50 Vs

Locked

Unlocked

+50.00 A — PSwitch Settings Lock

+0.50 Vs

Locked

Unlocked

+50.00 A — Quench Detect Lock

+0.50 Vs

Locked

Unlocked

+50.00 A — Quench Rate Lock

+0.50 Vs

Locked

Unlocked