beautypg.com

Appendix – American Magnetics 05100PS-430-601 Integrated Power Supply System User Manual

Page 185

background image

Rev. 5

167

Appendix

Power Supply Details

Isolation voltage

600 Vdc or peak

Either output terminal to ground.

Transient recovery for
load change

excursion

1% of Emax

50% load step 2A/microsecond max.

recovery

2 msec

Return to 0.1% of setting.

Turnon/turnoff overshoot

same as load transient response limits

Overvoltage protection

voltage

120% of Emax

Overcurrent protection

current

120% of Imax

Overtemperature protection

Shutdown

Open Load wire protection

Shutdown

GENERAL (ENVIRONMENTAL) SPECIFICATIONS

Temperature

operating

-20 to +50 deg C

Rated load. Derate at 25W per °C
between 50 and 70°C.

storage

-40 to +85 deg C

Cooling

3 internal dc fans

exhaust to the rear

Humidity

0 to 95% RH

non-condensing

Shock

20 g, 11msec +/- 50% half sine

non-operating

Vibration

5 -10 Hz

10mm double amplitude

3-axes, non-operating

10-55 Hz

2g

Altitude

sea level to 10000 ft.

0-3,000 ft: 100%, linear derating to
70% of power at 10,000ft.

Dimensions

English 1.735”H x 19"W x 17.5"D

Depth excluding connectors and ter-
minal blocks.

metric 44.45 x 482.6 x 443.7 mm

Weight

English 15 lbs

metric 6.82kg

Source power connector

IEC 320-C19 appliance inlet

250 Vac, 16A (VDE);
125 Vac, 20A (UL)

Load connections

Nickel plated copper busbars

Provision for safety covers.

Analog programming port.

15 pin D-sub

a. Current limited to 100 Adc (1000 W) per power supply unit by AMI system configura-

tion.

Table A-11.

Model 08150PS Power Supply Specifications (Continued)

Specification

Rating / Description

Condition