Remote Interface Reference

Ramp Configuration Commands and Queries

LOCK:ABsorber?

Returns “0” for Energy Absorber Present picklist value (under the Load

submenu) unlocked, or “1” for locked.

CONFigure:LOCK:BRIGHTness {0|1}

Specifies whether the Display Brightness picklist value (under the Misc

submenu) is locked or unlocked. Sending “0” unlocks. A “1” locks. “0” is the

default value.

LOCK:BRIGHTness?

Returns “0” for Display Brightness picklist value (under the Misc

submenu) unlocked, or “1” for locked.

CONFigure:LOCK:NETsetup {0|1}

Specifies whether the Net Setup submenu is locked or unlocked. Sending

“0” unlocks. A “1” locks. “0” is the default value.

LOCK:NETsetup?

Returns “0” for Net Setup submenu unlocked, or “1” for locked.

CONFigure:LOCK:CURRent:RATING {0|1}

Specifies whether the Magnet Current Rating picklist value (under the

LOAD submenu) is locked or unlocked. Sending “0” unlocks. A “1” locks.

“0” is the default value.

LOCK:CURRent:RATING?

Returns “0” for Magnet Current Rating picklist value (under the LOAD

submenu) unlocked, or “1” for locked.

CONFigure:LOCK:RAMPDown {0|1}

Specifies whether the External Rampdown Enabled picklist value (under

the LOAD submenu) is locked or unlocked. Sending “0” unlocks. A “1”

locks. “0” is the default value.

LOCK:RAMPDown?

Returns “0” for External Rampdown Enabled picklist value (under the

LOAD submenu) unlocked, or “1” for locked.

4.5.5

Ramp Configuration Commands and Queries

The ramp configuration commands set the various parameters required for

defining piecewise-linear ramp segments. The external rampdown

function also has the ramp segmenting capability. The function operates in

a manner similar to the normal ramp as described in section 3.7.1 on page

page 35, but parameters can only be edited via the remote interface. See