beautypg.com

Safety summary, Foreword – American Magnetics 05100PS-430-601 Integrated Power Supply System User Manual

Page 16

background image

xvi

Rev.

5

Foreword

Safety Summary

is 18-8 stainless steel. Copper, Monel

®

, brass and aluminum are also

considered satisfactory materials for cryogenic service.

Magnet Quenches

When an energized superconducting magnet transitions from

superconducting state to normal state, the magnet converts magnetic

energy to thermal energy thereby rapidly converting the liquid helium to a

vapor. When this phase transformation occurs, pressures can build rapidly

in the cryostat due to the fact that one part of liquid helium will generate

782 parts of gaseous helium at STP (standard temperature and pressure).

The cryostat must be designed to allow the generated vapor to rapidly and

safely vent to an area of lower pressure. Cryostats are designed with

pressure relief valves of sufficient capacity so as to limit the pressure

transients within the container in order to prevent damage to the vessel.

Operating a superconducting magnet in a cryostat without properly sized

relief mechanisms or disabled relief mechanism is unsafe for the operator

as well as for the equipment. If there is any doubt as to the sufficiency of

the pressure relief system, contact the manufacturer of the magnet and

cryostat for assistance.

Safety Summary

Superconducting magnet systems are complex systems with the potential

to seriously injure personnel or equipment if not operated according to

procedures. The use of cryogenic liquids in these systems is only one factor

to consider in safe and proper magnet system operation. Proper use of

safety mechanisms (pressure relief valves, rupture disks, etc.) included in

the cryostat and top plate assembly are necessary. Furthermore, an

understanding of the physics of the magnet system is needed to allow the

operator to properly control the large amounts of energy stored in the

magnetic field of the superconducting coil. The Model 430 Programmer has

been designed with safety interlocks to assist the operator in safe

operation, but these designed-in features cannot replace an operator’s

understanding of the system to ensure the system is operated in a safe and

deliberate manner.

Recommended Safety Equipment

First Aid kit

Fire extinguisher rated for class C fires

Cryogenic gloves

Face shield

Signs to indicate that there are potentially damaging magnetic fields

in the area and that cryogens are in use in the area.