Using the Tool
3.4 MIL Status
The MIL (Malfunction Indicator Lamp) Status function displays the
state of the computer module that commanded the MIL to turn on. A
request is sent to the computer module(s) to state whether they are
commanding the MIL to turn ON. If the MIL Status is ON and the MIL
is not illuminated with the engine running, then a problem exists in the
MIL circuit. Refer to “Diagnostic Circuit Check” in the service repair
manual.
Some
manufacturers
will
turn
the
MIL
Off
if
a
certain
number
of
drive
cycles
occur
without
the
same
fault
being
detected.
The
DTCs
related
to
a
MIL
are
erased
from
the
computer’s
memory
after
40
warm-up
cycles
if
the
same
fault
is
not
detected.
Select the MIL Status function and
press the ENTER key.
The MIL Status will display on the
top line and a scrolling message on
the bottom indicating if the MIL lamp
should be ON or OFF.
When done, press the BACK key to return to the Main Men
u.
3.5 I/M Monitors
The I/M (Inspection and Maintenance) Monitors function displays the
state of the vehicle’s OBD II Monitors. Monitors test the operation of
emission related systems or components and detect out-of-range
values. The vehicle may have to be operated under certain driving
conditions to initiate a monitor.
!
Main Menu
3)MIL Status
MIL - ON
MIL Lamp Should be On