Chapter 7 Basic Setting

73

7.3 General Setup

Use this screen to enter administrative details, time settings and login precedence. Click Basic
Setting
and General Setup in the navigation panel to display the screen as shown.

Hardware Monitor (The following hardware monitoring information is only available on the ES-

2108PWR.)

Temperature

Unit

The switch has temperature sensors that are capable of detecting and reporting if the

temperature rises above the threshold. You may choose the temperature unit

(Centigrade or Fahrenheit) in this field.

Temperature

CPU, MAC and LOCAL refer to the location of the temperature sensors on the switch

printed circuit board.

Current

This field displays the current temperature measured at this sensor.

MAX

This field displays the maximum temperature measured at this sensor.

MIN

This field displays the minimum temperature measured at this sensor.

Threshold

This field displays the upper temperature limit at this sensor.

Status

This field displays Normal for temperatures below the threshold and Error for those

above.

Fan speed

(RPM)

A properly functioning fan is an essential component (along with a sufficiently

ventilated, cool operating environment) in order for the device to stay within the

temperature threshold. Each fan has a sensor that is capable of detecting and

reporting if the fan speed falls below the threshold shown.

Current

This field displays this fan's current speed in Revolutions Per Minute (RPM).

MAX

This field displays this fan's maximum speed measured in Revolutions Per Minute

(RPM).

MIN

This field displays this fan's minimum speed measured in Revolutions Per Minute

(RPM). "<41" is displayed for speeds too small to measure (under 2000 RPM).

Threshold

This field displays the minimum speed at which a normal fan should work.

Status

Normal indicates that this fan is functioning above the minimum speed. Error

indicates that this fan is functioning below the minimum speed.

Voltage (V)

The power supply for each voltage has a sensor that is capable of detecting and

reporting if the voltage falls out of the tolerance range.

Current

This is the current voltage reading.

MAX

This field displays the maximum voltage measured at this point.

MIN

This field displays the minimum voltage measured at this point.

Threshold

This field displays the minimum voltage at which the switch should work.

Status

Normal indicates that the voltage is within an acceptable operating range at this point;

otherwise Error is displayed.

Table 9 System Info (continued)

LABEL

DESCRIPTION