2 load factory default, 3 save configuration, 2 load factory default 22.3 save configuration – ZyXEL Communications ZyXEL Dimension ES-2108 User Manual
Page 146: Figure 78 load factory default: confirmation

ES-2108 Series User’s Guide
146
Chapter 22 Maintenance
22.2 Load Factory Default
Follow the steps below to reset the switch back to the factory defaults.
1 In the Maintenance screen, click the Click Here button next to Load Factory Default to
clear all switch configuration information you configured and return to the factory
defaults. The following message appears.
Figure 78 Load Factory Default: Confirmation
2 Click OK to begin resetting all switch configurations to the factory defaults and then wait
for the switch to restart.
3 In the web configurator, click the Save button to make the changes take effect. If you
want to access the switch web configurator again, you may need to change the IP address
of your computer to be in the same subnet as that of the default switch IP address
(192.168.1.1).
22.3 Save Configuration
Save Configuration allows you to save your settings to the switch’s non-volatile memory.
Note: Whenever you make configuration changes to the switch and hit Apply or Add,
the switch saves the settings to its run-time memory. These settings are lost
when you restart the switch.
In the Maintenance screen, click the Config 1 button next to Save Configuration to save
your settings to the switch’s non-volatile memory. These settings are not lost when you restart
the switch. Alternatively, you can click the Save button on the top right corner of the web
configurator to save your settings to the switch’s non-volatile memory.
Save
Configuration
Click Config 1 to save the switch’s current configuration to non-volatile memory.
Reboot System
Click Config 1 to restart the switch without physically turning the power off.
Note: Make sure to click the Save button in any screen to save your
settings to the current configuration on the switch.
Table 50 Maintenance
LABEL