Reference, Function tree/function list – Yamaha DIGITAL MIXING STUDIO 01X User Manual
Page 84
84
01X Owner’s Manual
Before Using
Basics Section
Appendix
Getting Started
Reference
Reference
Function Tree/Function List
This chart shows the names, ranges and explanations of all settable parameters in the Internal mode, listed in order according
to the function tree. These parameters can be set not only from the 01X itself, but also conveniently from a computer—using
the included software program “Studio Manager” (see separate Installation Guide and PDF documentation).
• Operation procedures for calling up each parameter display are indicated in the chart ([button] → [button]).
• For information on the Display Indication and mode selection, see pages 37, 38.
• For information on the Remote mode, see page 104. For information on the “Home” operation, see page 37.
• To restore the default value of the selected parameter, simultaneously hold down the [SHIFT] button and press the appropri-
ate channel knob ([1] – [8]).
• Never attempt to turn off the power while data is being written to Flash ROM (while an “EXECUTING BACKUP. PLEASE
KEEP POWER ON...” message is shown). Turning the power off in this state results in loss of all user data and may
cause the system to freeze (due to corruption of data in the Flash ROM).
Chart Indications
The example below shows and describes the various indications in the Reference chart.
* These indications are for example purposes only, and differ from the actual chart.
A: These pages can be selected by using the DISPLAY [
/
] buttons.
...... Shows the pages (such as the first in a particular parameter category) that
can be jumped to by holding down the [PAGE SHIFT] button and pressing
DISPLAY [
] or [
].
B: Indicates the channel knob button to be used. For circled numbers (ex., q), turn the knob to change the parameter.
For boxed numbers (ex., z), press the knob to change the parameter. In some cases, both operations can be used.
The knob indicated in parentheses is used to change the parameter when the SELECTED CHANNEL lamp is lit.
C: Display indication (parameter ranges/settings).
D: Indicates whether a confirmation prompt is used or not. If “No” is shown here, the setting made takes place immedi-
ately. For certain parameters, the confirmation prompt can be enabled or disabled as desired; see page 95.
E: Indicates page numbers for relevant operations and details regarding the parameter.
F: Indicates the portion in the Block Diagram (at the end of the manual) to which the parameter applies.
[PAGE SHIFT] + DISPLAY [
/
]
Knob
Function name/
settings
Explanation
Prompt
Related
pages
Block
diagram
SCENE MODE [SCENE] → DISPLAY [
/
]
(or [SCENE] → [SCENE] → [SCENE])
1
SCENE LIBRARY
q
00 – 99
(Library number)
Determines the Library number. Preset Scene numbers and write-protected
Scenes are indicated by asterisks (*) in the display and cannot be changed.
Library number 00 is read-only and contains the default settings for all parame-
ters. By using Recall (below) to call up this Scene, you can restore all 01X set-
tings to their initial default state. This Scene can also be called up via an
external MIDI device by sending an appropriate program change message
(according to the setting in Program Change Assign Table; see page 94).
No
36
65
q
q – i
(y)
-18.0dB – +18.0dB
Adjusts the gain level. When Q is set to HPF, this turns the filter on or off.
Pressing the [EQ LOW] and [EQ HIGH] buttons simultaneously resets all band
parameters (gain, frequency and Q) for the selected channel.
Yes
w
[PAGE SHIFT] + DISPLAY [
/
]
A
B
C
D
E
F