beautypg.com

General data, Scrf/sirf 20-60 tons – Trane PKG-PRC002-EN User Manual

Page 19

background image

General Data

PKG-PRC002-EN

19

SCRF/SIRF
20-60 Tons

Table GD-4. SCRF/SIRF Air-Cooled Self-Contained

Unit Size

20

25

29

30

35

40

50

60

Compressor Data

Quantity

2

1/1

1/1

3

3

2/1

3

4

NominalTon/Comp

10

15/10

15/10

10

10

10/15

15

15

Circuits

2

2

2

2

2

2

2

2

Evaporator Coil Data

Rows

3

2

4

3

4

4

4

6

Sq. Ft.

21.81

29.98

29.98

31.35

31.35

38.57

49.09

49.09

Sq. m

(2.03)

(2.79)

(2.79)

(2.91)

(2.91)

(3.58)

(4.56)

(4.56)

FPF

144

144

144

120

144

144

144

144

Evaporator Fan Data

Quantity

1

1

1

1

1

1

1

1

Size (Dia. - inches)

16.5"

18.25"

18.25"

20"

20"

25"

25"

27.5"

Size (Dia. - mm)

(419.1)

(463.6)

(463.6)

(508)

(508)

(635)

(635)

(698.5)

Minimum HP

5

5

5

5

5

7.5

10

10

Minimum kW

(3.73)

(3.73)

(3.73)

(3.73)

(3.73)

(5.59)

(7.46)

(7.46)

Maximum HP

20

25

25

25

25

40

40

50

Maximum kW

(14.91)

(18.64)

(18.64)

(18.64)

(18.64)

(22.37)

(37.29)

(37.29)

Minimum Design CFM

6500

8700

8700

9100

9880

11960

15080

20800

Minimum Design liters / sec.

(3068)

(4106)

(4106)

(4295)

(4663)

(5645)

(7117)

(9817)

Maximum Design CFM

10625

12325

13600

14875

16150

19550

24650

29800

Maximum Design liters / sec.

(5014)

(5817)

(6418)

(7020)

(7622)

(9227)

(11634)

(14064)

General Data

EER

10.8

10.8

10.8

11.0

11.2

11.3

10.8

9.9

IPLV

11.8

12.1

11.4

12.8

12.6

12.5

12.0

10.0

Refrigerant Charge - lbs. R-22

57.2

66.7

72

57

57.2

66.7

72

72

Refrigerant Charge - kg R-22

(25.9)

(30.3)

(32.7)

(25.9)

(25.9)

(30.3)

(32.7)

(32.7)

Capacity Steps - %

100/53/0

100/62/39/0

100/59/39/0

100/65/31/0

100/65/30/0

100/70/41/30/0

100/65/30/0

100/73/46/20/0

Filter Data

Quantity

8

8

8

8

8

4

4

4

Size (inches)

20x18x2

20x18x2

20x18x2

20x18x2

20x18x2

16x20x2

16x20x2

16x20x2

Size (mm)

(508x457x51) (508x457x51)

(508x457x51)

(508x457x51)

(508x457x51)

(406x508x51)

(406x508x51)

(406x508x51)

Quantity

4

4

4

4

4

8

8

8

Size (inches)

20x20x2

20x20x2

20x20x2

20x20x2

20x20x2

16x25x2

16x25x2

16x25x2

Size (mm)

(508x508x51) (508x508x51)

(508x508x51)

(508x508x51)

(508x508x51)

(406x635x51)

(406x635x51)

(406x635x51)

Quantity

2

2

2

Size (inches)

20x20x2

20x20x2

20x20x2

Size (mm)

(508x508x51)

(508x508x51)

(508x508x51)

Quantity

4

4

4

Size

20x25x2

20x25x2

20x25x2

Size (mm)

(508x635x51)

(508x635x51)

(508x635x51)

CCRC/CIRC Unit Match

20

29

29

35

35

40

50

60

Notes:
1. Compressors are Trane 3D

®

scroll.

2. EER and IPLV are rated in accordance to the ARI Standard 340/360-93. Based on 80/67 F (26.7/19.4 C) to the evaporator coil, nominal airflow and 95 F (35 C) ambient.
3. All units operate with R-22. Units ships with a dry nitrogen holding charge.
4. Maximum cfm limits are set to prevent moisture carryover on the evaporator coil.
5. Minimum cfm limits are set to ensure stable thermal expansion valve operation at low load conditions.
6. Filter sizes are for units without hot water or steam heating coils

Table GD-5. SCRF/SIRF Refrigerant Circuits,
Number of Compressors by Circuit

Circuit 1

2

Unit Size
20 Ton

1-10T

1- 10T

25/29 Ton

1-15T

1-10T

30/35 Ton

2-10T

1-10T

40 Ton

1-10T, 1-15T

1-15T

50 Ton

2-15T

1-15T

60 Ton

2-15T

2-15T

Note: This table depicts compressor location in unit, plan

view from left corner