204

Commands and Responses for Controller Link Units

Section 6-5

Status 2 (response): For C200HX/HG/HE, CVM1, and CV-series Controller
Link Units, always set to 00 (Hex). For CS/CJ-series and CQM1H-series
PLCs, the Unit’s setting status is returning in the following configuration.

Status 3 (response): Error information. The configuration is as follows:

Note With CS/CJ-series Optical Controller Link Units, this bit will be 1, even if the

Unit is mistakenly connected to an Optical SYSMAC LINK Network.

Status 5 (response): Error information related to the Unit and the PLC. The
configuration is as follows:

A network parameter error, data link table error, or routing table error occurs if
an error is discovered when the parameters and tables are checked at power
up.

A PLC system setting errors occurs if the Controller Link Unit is not properly
recognized by a CS/CJ-series, CVM1, or CV-series PLC.

A PLC model error occurs if a C200HX/HG/HE Controller Link Unit is
mounted to another type of PLC.

Count 1 to Count 8 (response): The total number of times for each of the
items listed below is returned as 1 byte of hexadecimal data.

Count 1: Number of CRC errors
Count 2: Number of token re-sends
Count 3: Number of token returns
Count 4: Number of token timeouts
Count 5: Number of polling timeouts
Count 6: Number of controller changes
Count 7: Number of active node changes
Count 8: Reserved for system use.

Bit

Baud rate:
1 Hex: 2 Mbps
2 Hex: 1 Mbps
3 Hex: 500 Kbps

For Wired Units:

0: Terminating resistance OFF

1: Terminating resistance ON

1: Error log exists

1: Data link error stop

1: Controller transmitter error

1: Node address setting error

1: Duplicate node address setting error

1: Network parameter error (See note.)

1: Controller hardware error

7

0

6

5

4

3

2

1

0

Bit

1: EEPROM error

1: PLC model error
(C200HX/HG/HE only)

1: PLC system setting error
(CS/CJ-series, CVM1, and CV-series PLCs only)

1: Network parameter error

1: Data link table error

1: Routing table error

7

0

6

5

4

3

2

1

0

0

Bit