Chapter 2 System Architecture 
 
 
Page 2- 14
UNIVERGE
NEAX
2000 IPS
Request For Proposal (RFP) Reference Guide
Issue 6
System Power Supply and Cooling Fan
AC/DC Power Supply
 
The AC/DC Power Card is mounted in the rear side of each MODULAR CHASSIS. The AC/DC Power 
card provides power to all circuit cards, which are resided in the MODULAR CHASSIS. 
AC power requirements are as follows: 
 
Input Voltage: 85 to 264VAC, 50/60 Hz (Auto sensing 100V/200V selection) 
 
AC/DC Power Card
Description
Qty
Remarks
PZ-PW131
1 per MODULAR CHASSIS
AC/DC Power Supply 
Output:+5 V, 5.5A, -27 V, 3A 
 
Back-up Power 
 
UPS or battery backup (with external battery) is available for backup power for AC power failure. In 
case of battery backup, sealed type battery should be used. The open type battery is not available 
because of AC/DC power specifications. 
Required Battery Capacity
Battery Backup Time
Required Battery Capacity
10 minutes (Built-in battery)
12VDC, 0.8AH x 2
30 minutes (External battery)
12VDC, 2.2AH x 2
3 hours (External battery)
12VDC, 12AH x 2
Ring Generator Unit (RGU)
 
The RGU provides ringing supply to analog SLT (PN-4LCAA is no longer required); however, it cannot 
ring more than 6 analog SLT’s per MODULAR CHASSIS simultaneously. Therefore, the simultaneous 
ringing has to be limited by office data setting. 
Ring Generator Unit (RGU) Card
Description
Qty
Remarks
PZ-PW139 MODULAR
CHASSIS
Ring Generator Unit 
Ring Voltage: 85/75Vac 
Ring Current: 0.05A 
Cooling FAN
 
The cooling FAN is mounted at the right side of each MODULAR CHASSIS. The FAN should be 
replaced every 4 years in order to ensure the cooling system. 
 
Cooling FAN
Description
Qty
Remarks
109P0624H 
7D09 FAN 
1 per MODULAR CHASSIS
Each Modular Chassis is equipped with a 
Cooling Fan this part is for replacement only 