2000 IPS SYSTEM POWER SUPPLY
AC/DC Power Supply
 
The AC/DC Power Card is mounted in the left side of each PIM. The AC/DC Power card provides 
power to all circuit cards, which reside in the PIM. AC power requirements are as follows: 
 
Input Voltage: 90 to 132 Vrms or 180 to 264 Vrms (selectable by switch) 50/60 Hz 
AC/DC Power Card
Name Code
Qty
Remarks
PZ-PW121
1 per PIM
AC/DC Power Supply Input:100 V/200 V 
Output:+5 V,-27 V,+90V, CR 
DC/DC Power Unit
The DC/DC Power Unit is mounted under the AC/DC Power Card and generates -48 V power for the 
circuit cards that need such power
.
DC/DC (-48V) Power Card
Name Code
Qty
Remarks
PZ-PW122
1 per PIM
DC/DC Power Supply, Input: -27 V, Output: -48 V
Battery Backup
Internal Short-term option
 
For customers requiring battery backup, short-term and/or long-term options are available. Two 3.4AH 
batteries are required per PIM, and installed inside of each PIM. Backup time is approx. 30 minutes 
when PHS (Wireless PS) is not accommodated and approx. 10 minutes when PHS (Wireless PS) is 
accommodated in the system. 
Internal Battery Option
Name Code
Qty
Remarks
PWR CA-A
1 per (2) PIM’s DC Power Cable (-27v input)
BATT CA INT
1 per PIM
Internal Battery Cable
External Long-term option
Two 24AH batteries are required per each 2 PIM’s, and installed inside of Battery Module in a stack 
basis. Backup time is approx. 3 hours when PHS (Wireless PS) is not accommodated and approx. 2 
hours when PHS (Wireless PS) is accommodated in the system. The batteries are varied depending 
on the requested backup time. The battery shall be locally provided
.
External Battery Option
Name Code
Qty
Remarks
PWR CA-A
(No. of PIM) –1= up to 4PIM 
(No. of PIM) –2= 5 to 8PIM 
DC Power Cable (-27v input)
BATT CA EXT
1/Stack
External Battery Cable