ISDN PRI Specifications
DTI
The Digital Trunk Interface (DTI) interfaces the PBX directly to 24/30-channel PCM transmission line.
The DTI has the following functions.
For 24DTI:
•
Two Directory numbers, each with a SPID
•
Unipolar/Bipolar Conversion (AMI/B8ZS Format)
•
Alarm Detection/Insertion
•
Digital PAD on Voice Signal Transmission
•
Loop-Back Test (Local/Remote Loop Back)
•
Cyclic Redundancy Checking (based on ITU-T Rec. G704)
For 30DTI:
•
Unipolar/Bipolar Conversion (HDB3 Format)
•
Alarm Detection/Insertion
•
Digital PAD on Voice Signal Transmission
•
Loop-Back Test (Local/Remote Loop Back)
•
Cyclic Redundancy Checking (based on ITU-T Rec. G704)
For connections of 24DTI and transmission line, twisted-pair cable can be used. For connection of
30DTI and transmission line, either coaxial cable or twisted pair cable can be used.
DCH
The D-Channel Handler (DCH) provides the D-Channel signaling interface through the DTI to an ISDN
exchange, and it is responsible for signaling between the PBX and the ISDN exchange under control of
the system MP.
PRT
The Primary Rate Interface Trunk (PRT) provides the ISDN Primary Rate Interface (1.5 Mbps PCM-23B
+ D/2 Mbps PCM-30B + D) and a built-in D-Channel Handler (DCH). The PRT has the following
functions.
For 24PRT:
Unipolar/Bipolar Conversion (AMI/B8ZS Format)
Alarm Detection/Insertion
Digital PAD on Voice Signal Transmission
Loop-Back Test (Local/Remote Loop Back)
Cyclic Redundancy Checking (based on ITU-T Rec. G704)
For 30PRT:
Unipolar/Bipolar Conversion (HDB3 Format)
Alarm Detection/Insertion
Digital PAD on Voice Signal Transmission
Loop-Back Test (Local/Remote Loop Back)
Cyclic Redundancy Checking (based on ITU-T Rec. G704)