Wireless specifications – NEC UNIVERGE NEAX 2000 IPS User Manual
Page 337
Chapter 16 Wireless System
UNIVERGE
NEAX
2000 IPS Request For Proposal (RFP) Reference Guide Page 16-15
Issue 6
Wireless Specifications
Zone Transceiver II Specifications
ITEM
SPECIFICATIONS
• ZT II U
Output Power
6.8 mW
Type of Interface
U Interface
Number of Simultaneous Speech Path
Maximum 3
Power Supply
• PBX Power Supply (DC –48 V)
• Local Power Supply (AC 100 V/200 V)
Power Consumption
Maximum 3 W
Operating Conditions
Ambient Temperature: –10 50 °C
Relative Humidity : 45 - 85 % (non-condensing)
Installation Location : Indoor
Dimensions (unit: mm)
160 (W) x139 (D) x40 (H) (Excluding Antenna)
Weight Approx.
400
g
Wire Diameter
26 AWG
24 AWG
22 AWG
19AWG
2W
2500 ft.
(762 m)
4000 ft.
(1219 m)
5500 ft.
(1676 m)
8000 ft.
(2438 m)
PBX Power
Supply at -48 V
4W
4300 ft.
(1310 m)
6900 ft.
(2103 m)
9500 ft.
(2895 m)
13000 ft.
(3958 m)
2W
2000 ft.
(609 m)
3200 ft.
(975 m)
4700 ft.
(1432 m)
7000 ft.
(2131 m)
PBX Power
Supply at -45 V
4W
3500 ft.
(1066 m)
5600 ft.
(1706 m)
8200 ft.
(2499 m)
12200 ft.
(3718 m)
2W
1800 ft.
(548 m)
2900 ft.
(883 m)
4400 ft.
(1340 m)
6400 ft.
(1948 m)
PBX Power
Supply at -43 V
4W
3100 ft.
(944 m)
5000ft.
(1524 m)
7600 ft.
(2316 m)
11000 ft.
(3352 m)
Local Power Supply
11000 ft.
(3350 m)
13000 ft.
(3958 m)
13000 ft.
(3958 m)
13000 ft.
(3958 m)
System Capacity
Capacity
Integrated
Adjunct (Analog)
Adjunct (CCIS)
Description
1PIM
2PIM 3PIM 4PIM 5PIM 6PIM 7PIM 8PIM
Zone
Transceiver
(ZT)
16 32 48 64 80 96 112 128
Dterm PS
Note
512
CSI 4CSIA-A
32
CSH
24
PS Simultaneous Connections
216
Calling Area
32
ZT per Calling Area
128
Note:
All existing CSH cards in a system should be SPN-SC03B 8CSH-C (AP) when accommodating