Hotel system capacity, System specifications – NEC UNIVERGE NEAX 2000 IPS User Manual
Page 353
Chapter 17 Hotel/Motel System
UNIVERGE
NEAX
2000 IPS Request For Proposal (RFP) Reference Guide Page 17-13
Issue 6
Hotel System Capacity
Description
Capacity
Guest/Administrative Station
1020
Front Desk Terminal
8
Hotel Console
8
Hotel Printer
2
I/O port for PMS/SMDR/Hotel Printer
2
I/O port for SMDR/PMS via LAN
1
I/O port for Hotel Printer
2
System Specifications
PMS/SMDR via RS-232C Interface (Model 60 only) and Hotel Printer Interface
Specifications
Item
PMS/SMDR Interface
Hotel Printer Interface
Physical Interface
RS-232C
RS-232C
Synchronization Asynchronous
Asynchronous
Protocol IMS
Procedure
—
Transmission Speed
1200/2400/4800/9600 bps
Note
1200/2400/4800 bps
I/O port
No. 0-3 port of AP00-B card
No. 0/3 port of AP00-B card
Note:
For the port 1 and port 3 of AP00-B card with AP00 program, data speed cannot be set to 9600 bps.
PMS/SMDR via LAN Interface (Model 90/120 only)
Item
Specifications
Physical layer
Ethernet
Connection layer
Ethernet packet format complies with the DIX standard.
TCP/IP protocol
ARP, IP, ICMP, UDP, TCP
Socket interface
Complies with 4.3 BSD socket interface
Transport protocol
TCP stream type protocol
Application port number
SMDR: 60010 (fixed)
PMS : 60050 (fixed)
Number of connections
1
Client/Server
Client : SMDR/PMS terminal
Server: PBX
Transmission code
7-bit ASCII code
Quasi-normal restriction condition
1. When connection is closed
2. Status monitoring text