Property management system (pms) – NEC UNIVERGE NEAX 2000 IPS User Manual
Page 204
Chapter 10 System Input/Output (I/O) Interfaces
Page 10-8
UNIVERGE
NEAX
2000 IPS
Request for Proposal (RFP) Reference Guide
Issue 6
Property Management System (PMS)
The system provides a data interface to a locally provided Property Management System
(PMS). This enables communication between the system and the PMS in order to provide
computer control of Hotel/Motel features.
The available PMS feature codes:
PMS
Feature
Feature
Code
Type of Information
AP00
IP
11
Maid status set up by guest room telephones
Maid Status
12
Maid status set up by the Front Desk Terminal
X
X
Message Waiting
13
Message waiting lamp status changes
X
X
Station Message Detail
14
Local/toll call details on completion of calls
X
X
Restriction Control
15
Changes in telephone calling restrictions
placed on room station numbers
X
—
Check In/Check Out
16
Room check in/check out status
X
X
Room Data Image
17
Complete status information for a room
X
X
Wake Up
19
Wake up status
X
X
Room Change/Room
Swap/Room Copy
20
Room change/room swap status
X
X
Room Occupancy/
Room Data Change
21
Room Occupancy/Room Data Changes
X
—
Data Connection
Maintenance
50 Batch
processing
status
—
X
Message Waiting
53
Controlling message waiting lamps
—
X
Station Message Detail
54
Station message detail information for each call
—
X
Check In/Check Out/Room
Change
56
Setting check in/check out and room change
—
X
Room Recovery
57
Room information at system recovery
—
X
Direct Data Entry
59
Data entered from a guest room station
X
X
Room Data Change
61
Room data change information
—
X
Administrative
Station Name
65
Setting administrative station name
—
X
Status Inquiry
70
Data link maintenance
X
X
X: Available —: Not available