Business System Capacities
Capacities
Item ACD
CallCenterWorX
ACD 3.0
CallCenterWorX
MIS 3.0
Tenants per System
9
Splits per ACD Tenant
Note 1
Note 1
Splits per System
150
150
Splits per Logon ID
32
32
Active ACD Agents per
System
120 Note 2/ Note 4
120 Note 2
Trunks per System
255 Note 4
255
Maximum Queue Depth
300
–
Priority Levels 1
250
Note 3
Maximum Calls in
Queue per System
300 –
Transfer to PBX
Numbers
120 –
Agent Logon ID Codes
per System
400 400
Agent Logon ID Code
Digits
9 9
Statistics Report History
Limit
–
1.5GB
MIS per System
8
8
Pilot Numbers
300 Note 4 300
Tally Code Names per
Split
– 100
Tally Code Names per
System
– 3000
Busy Hour Call Attempts
(BHCA)
Note 5
–
Note 1
:
The total number of splits per system (150) is shared among the total number of tenants (up to 9).
Note 2: Agent positions available depend on the installed security key’s capacity for logged-on agents. The
total number of agents is shared among the total number of tenants (up to 9). Security keys are available in
the following capacities: 10, 20, 30, 40, 60, 80, 100, & 120.
Note 3: The MIS tracks Split queue calls as “High” and “Standard.”
Note 4: Dependent upon the CallCenterWorX configuration formula based on the OAI monitoring limitations:
(Agents x 2) + (Pilots and/or Personal Pilots) + Trunks + IVR Ports must be equal to or less than 256.
Note 5:
BHCA (Busy Hour Call Attempts)
Number of PIM’s
1PIM
2PIM
3PIM
4PIM
5PIM
6PIM
7PIM
8PIM
Business or
Hotel/Motel
with ACD/OAI
Max. 2000 BHCA
(No FP)
Max. 4000 BHCA
(One FP)
Max. 5000 BHCA
(Two FPs)
Max. 5500 BHCA
(Three FPs)