7-14

POST Error Messages

Powering on the server automatically starts the self-diagnostic program, POST (Power On
Self-Test). When POST detects any error, it displays an error message and its measure on the
display unit. Follow the table below to troubleshoot such errors.

Phoenix BIOS 4.0 Release 6.0.XXXX

:

CPU=Pentium III XXX MHz

0640K System RAM Passed

0127M Extended RAM Passed

WARNING:

02B0: Diskette drive A error.

:

press to resume, to SETUP

Message indicating a floppy disk drive error

TIPS:

For error messages on optional PCI board, refer to the manual provided with those

options.

On-screen error message

Cause

Action

0200 Failure Fixed Disk

Configuration error in

Setup menu.

Hard disk is faulty.

CPU module board is

faulty.

PCI module board is

faulty.

Check configuration in

Setup menu.

Replace the hard disk.

Replace the CPU module

board.

Replace the PCI module

board.

0210 Stuck Key

Keyboard connection error

Disconnect the keyboard

and connect it back again.

Replace the keyboard.

Replace the PCI module

board.

0211 Keyboard error

Keyboard is faulty.

0212 Keyboard Controller

Failed

Keyboard controller is faulty.

Check the keyboard

connection.

Restart the server.

Replace the PCI module

board.

0213 Keyboard locked -

Unlock key switch

Keyboard is locked.

Unlock the key switch.

0220 Monitor type does not

match CMOS - Run
SETUP

Illegal monitor type is
specified.

Select "Get Default Value"

from the Setup menu.

Clear the CMOS data.

0230 System RAM Failed at

offset

DIMM is faulty.

Replace DIMM.

Replace the CPU module

board.

0231 Shadow RAM Failed at

offset

DIMM is faulty.

Replace DIMM.

Replace the CPU module

board.