Post error messages, Tips – NEC Express 5800/320Lb User Manual
Page 218

7-14
POST Error Messages
Powering on the server automatically starts the self-diagnostic program, POST (Power On
Self-Test). When POST detects any error, it displays an error message and its measure on the
display unit. Follow the table below to troubleshoot such errors.
Phoenix BIOS 4.0 Release 6.0.XXXX
:
CPU=Pentium III XXX MHz
0640K System RAM Passed
0127M Extended RAM Passed
WARNING:
02B0: Diskette drive A error.
:
press
Message indicating a floppy disk drive error
TIPS:
For error messages on optional PCI board, refer to the manual provided with those
options.
On-screen error message
Cause
Action
0200 Failure Fixed Disk
•
Configuration error in
Setup menu.
•
Hard disk is faulty.
•
CPU module board is
faulty.
•
PCI module board is
faulty.
•
Check configuration in
Setup menu.
•
Replace the hard disk.
•
Replace the CPU module
board.
•
Replace the PCI module
board.
0210 Stuck Key
Keyboard connection error
•
Disconnect the keyboard
and connect it back again.
•
Replace the keyboard.
•
Replace the PCI module
board.
0211 Keyboard error
Keyboard is faulty.
0212 Keyboard Controller
Failed
Keyboard controller is faulty.
•
Check the keyboard
connection.
•
Restart the server.
•
Replace the PCI module
board.
0213 Keyboard locked -
Unlock key switch
Keyboard is locked.
Unlock the key switch.
0220 Monitor type does not
match CMOS - Run
SETUP
Illegal monitor type is
specified.
•
Select "Get Default Value"
from the Setup menu.
•
Clear the CMOS data.
0230 System RAM Failed at
offset
DIMM is faulty.
•
Replace DIMM.
•
Replace the CPU module
board.
0231 Shadow RAM Failed at
offset
DIMM is faulty.
•
Replace DIMM.
•
Replace the CPU module
board.