NEC Express 5800/320Lb User Manual
Page 209
7-5
STATUS LED
Indication
Color State
Suspected
module
Explanation Procedure
Cor0 +5.0vAlm
09
Amber
Lit
PCI module #1
Fatal
5-V power voltage alarm
(upper limit)
Cor0 +5.0vsAlm
00
Amber Blink PCI module #1
5-V power voltage alarm
(lower limit)
Cor0 +5.0vsAlm
02
Amber
Lit PCI module #1
Fatal
5-V power voltage alarm
(lower limit)
Cor0 +5.0vsAlm
07
Amber Blink PCI module #1
5-V power voltage alarm
(upper limit)
Cor0 +5.0vsAlm
09
Amber
Lit
PCI module #1
Fatal
5-V power voltage alarm
(upper limit)
Cor0 -12vAlm 00 Amber Blink PCI module #1
-12-V power voltage alarm
(lower limit)
Cor0 -12vAlm 02 Amber
Lit
PCI module #1
Fatal -12-V power voltage
alarm (lower limit)
Cor0 -12vAlm 07 Amber Blink PCI module #1
-12-V power voltage alarm
(upper limit)
Contact your sales agent.
Cor0 -12vAlm 09 Amber
Lit
PCI module #1
Fatal -12-V power voltage
alarm (upper limit)
Cor0 Bus PERR 01 Green Blink PCI module #1
PCI bus parity error
Cor0 Bus SERR 01 Green Blink PCI module #1
Fatal PCI bus error
Cor0 CLK Alm 00 Amber Blink CLOCK
board
Clock alarm (lower limit)
Cor0 CLK Alm 02 Amber Lit CLOCK
board
Fatal Clock alarm (lower
limit)
Cor0 CLK Alm 07 Amber Blink CLOCK
board
Clock alarm (upper limit)
Cor0 CLK Alm 09 Amber Lit CLOCK
board
Fatal Clock alarm (upper
limit)
Contact your sales agent.
Cor0 FAN Alm 01 Amber Blink PCI module #1
Cooling fan1 alarm
Cor0 FAN Alm 02 Amber Blink PCI module #1
Cooling fan2 alarm
Cor0 FAN Alm 03 Amber Blink PCI module #1
Cooling fan3 alarm
Cor0 FAN Alm 04 Amber Blink PCI module #1
Cooling fan4 alarm
Cor0 FAN Alm 05 Amber Blink PCI module #1
Cooling fan5 alarm
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.
Cor0 offline
Green Blink PCI module #1
PCI module logically isolated Start the PCI module by ft
sever utility or dismount
and remount that module.
If not solved by the above,
contact your sales agent.
Cor0 removed
Green Blink PCI module #1
PCI module detached
Dismount and remount the
PCI module. If not solved
by the above, contact your
sales agent.
Cor0 Temp Alm 00 Amber Blink PCI module #1
Temperature alarm (lower
limit)
Cor0 Temp Alm 02 Amber
Lit
PCI module #1
Fatal temperature alarm
(lower limit)
Cor0 Temp Alm 07 Amber Blink PCI module #1
Temperature alarm (upper
limit)
Cor0 Temp Alm 09 Amber
Lit
PCI module #1
Fatal temperature alarm
(upper limit)
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.