beautypg.com

NEC Express 5800/320Lb User Manual

Page 213

background image

7-9

STATUS LED

Indication

Color State

Suspected

module

Explanation Procedure

CPU0 +5.0vAlm
07

Amber Blink CPU module #1 5-V power voltage alarm

(upper limit)

CPU0 +5.0vAlm
09

Amber

Lit

CPU module #1 Fatal 5-V power voltage alarm

(upper limit)

CPU0 +5.0vsAlm
00

Amber Blink CPU module #1 5-V power voltage alarm

(lower limit)

CPU0 +5.0vsAlm
02

Amber

Lit

CPU module #1 Fatal 5-V power voltage alarm

(lower limit)

CPU0 +5.0vsAlm
07

Amber Blink CPU module #1 5-V power voltage alarm

(upper limit)

CPU0 +5.0vsAlm
09

Amber

Lit

CPU module #1 Fatal 5-V power voltage alarm

(upper limit)

CPU0 broken

Green Blink CPU module #1 CPU module breakdown

Contact your sales agent.

CPU0 FAN Alm 01 Amber Blink CPU module #1 Cooling fan1 alarm
CPU0 FAN Alm 03 Amber Blink CPU module #1 Cooling fan2 alarm
CPU0 FAN Alm 04 Amber Blink CPU module #1 Cooling fan3 alarm

Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.

CPU0 offline

Green Blink

CPU module #1 PCI module logically isolated Start the PCI module by ft

sever utility or dismount
and remount that module.
If not solved by the above,
contact your sales agent.

CPU0 removed

Green Blink

CPU module #1 PCI module detached

Dismount and remount the
PCI module. If not solved
by the above, contact your
sales agent.

CPU0 Temp Alm 00 Amber Blink CPU module #1 Temperature alarm (lower

limit)

CPU0 Temp Alm 02 Amber

Lit

CPU module #1 Fatal temperature alarm

(lower limit)

CPU0 Temp Alm 07 Amber Blink CPU module #1 Temperature alarm (upper

limit)

CPU0 Temp Alm 09 Amber

Lit

CPU module #1

Fatal temperature alarm

(upper limit)

Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.

CPU0 VccpAlm 00

Amber

Blink CPU module #1 CPU operating voltage alarm

(lower limit) (VCCP)

CPU0 VccpAlm 02

Amber

Lit

CPU module #1

Fatal CPU operating voltage

alarm (lower limit) (VCCP)

CPU0 VccpAlm 07

Amber

Blink CPU module #1 CPU operating voltage alarm

(upper limit) (VCCP)

CPU0 VccpAlm 09

Amber

Lit

CPU module #1

Fatal CPU operating voltage

alarm (upper limit) (VCCP)

CPU0 Vtt Alm 00

Amber

Blink CPU module #1 1.25-V power voltage alarm

(lower limit)

CPU0 Vtt Alm 02

Amber

Lit

CPU module #1

Fatal 1.25-V power voltage

alarm (lower limit)

CPU0 Vtt Alm 07

Amber

Blink CPU module #1 1.25-V power voltage alarm

(upper limit)

CPU0 Vtt Alm 09

Amber

Lit

CPU module #1

Fatal 1.25-V power voltage

alarm (upper limit)

Contact your sales agent.

This manual is related to the following products: