beautypg.com

Figure 16 cs 1000 sip uri map – Nortel Networks NN43001-321 User Manual

Page 63

background image

CS 1000 SIP configuration and UDP location dialing

63

Note: The fields require a character string that is less than 128
characters in length. The valid characters include: alphanumeric
(a-z, 0-9), period (.), dash (-), underscore (_), and plus sign
(+). These fields must be completed if the SIP Trunk Gateway
application is enabled.

Figure 16
CS 1000 SIP URI Map

7

Fill in the fields as follows:

a. Type +1 in the Public E.164/National domain name text box.

b. Type +1613 in the Public E.164/Subscriber domain name text

box.

c. Type publicUnknown in the Public E.164/Unknown domain

name text box.

d. Type publicSpecial in the Public E.164/Special Number

domain name text box.

e. Type udp in the Private/UDP domain name text box.

f.

Type cdp.udp in the Private/CDP domain name text box.

g. Type special.udp in the Private/Special Number domain

name text box.

h. Type privateUnknown in the Private/Unknown (vacant

number routing) domain name text box.

i.

Type unknown.unknown in the Unknown/Unknown domain
name
text box.

Note: The values entered in these fields must agree with values
entered in MCS 5100. See

"Configure number qualifiers" (page

72)

.

Nortel Communication Server 1000

Communication Server 1000 to MCS 5100 Converged Desktop Type 2 Configuration Guide

NN43001-321

01.05

Standard

Release 5.0

15 February 2008

Copyright © 2005-2008, Nortel Networks

.