Nortel Networks NN43001-321 User Manual
Page 51
CS 1000 SIP configuration and UDP location dialing
51
Prompt
Response
Description
-PFX1
613
Prefix 1
-PFX2
962
Prefix 2
DITI
Yes
DID to TIE connections allowed.
To connect external DID and internal network TIE trunks
for the customer (which allows an external trunk to be
transferred across an internal network TIE trunk), set
DITI=YES.
LD 17 Configure the Application Module Link (AML).
Prompt
Response
Description
REQ
CHG
Change existing data.
TYPE
ADAN
Action Device And Number
- ADAN
NEW ELAN x
Action Device And Number
Where x is the ELAN Link number:
x = 32 to 47 (inclusive) for Small Systems
x = 32 to 127 (inclusive) for Large Systems
AML link number within the preceding range implies that
the transport is over TCP/RUDP link.
CTYP
ELAN
AML over Ethernet card type
LD 17 Configure Value Added Server (VAS).
Prompt
Response
Description
REQ
CHG
Change existing data.
TYPE
VAS
Value Added Server configuration
VAS
NEW
New Value Added Server data block
- VSID
32-500
VAS Identifier
= 32 to 47 for Small Systems
= 32 to 127 for Large Systems
Nortel recommends that the VAS Identifier match the
ELAN Link number configured in the last step (LD 17 —
Configuring AML).
- ELAN
x
Associate Value Added Server ID (VSID) x with Application
Module Link over Ethernet (ELAN) x
Note: The AML ELAN link number must match the number
provisioned in the last step (LD 17 — Configuring AML).
Nortel Communication Server 1000
Communication Server 1000 to MCS 5100 Converged Desktop Type 2 Configuration Guide
NN43001-321
01.05
Standard
Release 5.0
15 February 2008
Copyright © 2005-2008, Nortel Networks
.