p. 127
microprocessor muting system
features
mute controller
E—
SINGLE SCENE
There are nine
MUTE
sources available from the
MUTE CONTROLLER
:the eight
MANUAL MUTE SCENES
H, and the
MICRO SCENE
G. Normally any or all of
these nine sources can be active at-one-time, which allows the operator
to combine different mute patterns. The
SINGLE SCENE
switch, when
depressed, permits only one of the nine-sources to be active at-one-time.
F—
MICRO UTILITY
This latching switch will put the system into
UTILITY
mode.The operator
can then access and view the various parameters and functions of the con-
troller using the
UP
/
DOWN
buttons A and the
DISPLAY
B.
G—
MICRO SCENE
This switch activates the
SEQUENCED SCENE
(
PATCH
).
The
DISPLAY
B shows which of the 128 possible
SCENES
are active.
H—
MANUAL MUTES
These eight switches activate the associated
MANU
-
AL MUTE SCENE
.Additionally, these switches, along with G, select which
MUTE
SCENE
is being edited when in
EDIT
/
PREVIEW
mode.
I—
RECALL
(
NEXT
)
Each press of this switch increments the
SEQUENCED
MUTES
by one, the
DISPLAY
B will reflect this.Also used to activate the dis-
played scene when an
UP
/
DOWN
A button was used to scroll to a new
scene. In this case, an * will be displayed as the first-character in the display
to indicate that the displayed number is not currently the active scene.
Pressing
RECALL
will put that displayed
SCENE
into place and clear the *
from the display.
All of these actions
will take place, but
the displayed
SEQUENCED
SCENE
will not be active
(mutes not enabled)
—unless the
MICRO SCENE
switch G is lit.
+