Operational mode, Clock modes – Interphase Tech RAS Communications Controller 5536 User Manual
Page 188
Setting Port and Clock Modes
168
Interphase Corporation
When this mode is selected, the text message portion of the
Line Test main dialog box displays the following
synchronization results:
Operational Mode
After a test has completed, you must return the port used for
testing to Operational mode so that it can handle incoming and
outgoing communications.
To return the port to Operational mode, select Operational
mode on the Port Test Configuration dialog box (shown in
).
Before closing the Line Test utility, you are requested to
restore each port in testing mode to the operational mode.
Clock Modes
In some test configurations (such as back-to-back
configurations), a port must use the remote card clock to
successfully synchronize on the received signal.
Message
Meaning
No error
The receiving bit sequences completed, and
the port found no errors when comparing
sent and received bit sequences.
X bits in error/sec
The port is comparing received bit
sequences with sent bit sequences.
Each erroneous bit found is added, and the
sum is displayed each second.
Not synchronized
The port is unable to recognize what it sent.