Saving and editing frames – Interphase Tech RAS Communications Controller 5536 User Manual
Page 171
![background image](/manuals/128405/171/background.png)
Appendix B: Using the SynWatch Utility
5536 PRI RAS Communications Controller Users Guide
151
2. In the Buffer Type section, select one of the following
options:
– Select Stop when full to have SynWatch store only
the first events up to the specified number in the
Buffer Size field.
– Select Circular to have SynWatch store new events
after reaching the number specified in the Buffer
Size field by deleting the older events to maintain the
limit.
3. In the Number of Events section, enter the number of
low-level events to be stored in the internal buffer.
Saving and Editing Frames
Use the SynWatch Save option to save all frame information
recorded in the monitor panel as an ASCII (text) or binary file.
You can read a text file using any text editor, but SynWatch
cannot read or reinterpret the text file. On the other hand,
SynWatch can read or reinterpret a binary file.