IBM DS6000 User Manual
Page 557

Appendix D. CLI migration
533
Table D-2 ESS and DS CLI commands and parameters comparison
ESS CLI
DS CLI
Comments
list server
lsserver
Like the 2105, the 1750 storage
facility image contains one pair
of servers.
list volumespace
lsextpool, showextpool, lsrank,
showrank, lsarray, showarray,
lsarraysite
See Note 1
create volumespace
mkextpool, mkarray, mkrank
delete volumespace
rmrank, rmarray, rmextpool
list diskgroup
lsarraysite
A 1750 Array Site can consist of
at least four disk drives (DDMs)
that are made into a RAID
Array. The 1750 does not
support the JBOD Array
configuration.
list port
lsioport, showioport
The 1750 CLI lsioport and
showioport commands include
the –metrics parameter that
returns the performance
counter values for the
respective I/O port IDs. The
–metrics parameter provides
the means to monitor I/O port
performance statistics.
set port
setioport
See Note 2
list volume
lsfbvol, lsckdvol
See Note 3
create volume
mkfbvol, mkckdvol
set volume
chfbvol, chckdvol
list pav
lsckdvol, showckdvol
create pav
mkckdvol
delete pav
rmckdvol
list volumeaccess
lsvolgrp, showvolgrp
See Note 4
create volumeaccess
mkvolgrp, chvolgrp
delete volumeaccess
rmvolgrp
list hostconnection
lshostconnect,
showhostconnect
The 1750 CLI commands
include the volume group ID
parameter.
For 2107, the hostconnect
commands concern SCSI-FCP
host port connections to ESS
I/O ports that are configured for
SCSI-FCP and “identified”
access mode.
create hostconnection
mkhostconnect
delete hostconnection
rmhostconnect
set hostconnection
chhostconnect
list log
N/A