IBM System Storage DS6000 Series: Copy Services with IBM System z

Once the local site is ready, quiesce the application at the remote site. Then a sequence of
Failover - Failback operations from A to B will reestablish Global Copy back as it was
originally before the local site outage.

Figure 23-17 shows the action at the local site, the Failover operation from A to B. This will
change the state of the A volumes from secondary pending to primary suspended, and start
to keep a bitmap record of the changes to the A volumes.

Once the Failover is completed, a Failback operation from A to B is done; see Figure 23-18.

Figure 23-18 Failback from A to B and resync Global Copy volumes

Figure 23-18 shows the Failback operation at the local site. This will change the state of the B
volumes from primary pending to secondary pending, and start to replicate updates from A to
B.

In our example, the application did not start yet at this point, so there are no updates at the
local site. The state of the local volumes A will quickly change from primary suspended to
primary pending, which is the normal state for Global Copy pairs.

Figure 23-19 Establish Global Mirror FlashCopy relationship between B and C

Global Copy

Primary

Primary

A

Primary

Primary

A

Tertiary

C

Primary

Primary

A

Primary

Primary

A

B

Remote site

Host

Primary

Primary

A

Primary

Primary

A

A

Secondary

PENDING

Resync from A to B

Host

Primary

PENDING

Failback A to B

Local site

Global Copy

Primary

Primary

A

Primary

Primary

A

Tertiary

C

Primary

Primary

A

Primary

Primary

A

B

Remote site

Primary

Primary

A

Primary

Primary

A

A

Secondary

PENDING

Host

Primary

PENDING

FlashCopy

Local site