beautypg.com

IBM SY27-0345-06 User Manual

Page 27

background image

006

– Go to Step 012.

007

Run an external wrap test on the port. For assistance, go to “Operational
Diagnostics” on page 3-2.

Is the port amber LED blinking?
Yes No

008

There is a problem with the software or with the network. Contact your next
level of support for instructions about reviewing the system error log.

009

Were the wrap plugs installed correctly during the Extended POST?
Yes No

010

Repeat the Extended POST using the wrap plugs correctly. Take any action
that is indicated.

011

Replace the system board. Then, go to “MAP 0210: Verify Operation” on
page 2-23.

012

Is an amber port LED blinking?
Yes No

013

Go to Step 023 on page 2-6.

014

– If this is the primary service port on the 14T and 24x models, continue at “MAP

0170: Primary Service Port on 14T or 24x Model Is Not Working” on page 2-14.

– If this is the secondary service port on the 14T or 24x models, continue at “MAP

0180: Second Service Port Is Not Working” on page 2-15.

– If this is an optional adapter, continue at “MAP 0200: Optional Adapter or Dial

Access Adapter Is Not Working” on page 2-21.

(Step 014 continues)

Chapter 2. Problem Determination

2-5