B. After attaching both mounting brackets, position the MIL-SM2401M-STK in

the rack by lining up the holes in the brackets with the appropriate holes on

the rack. Secure the switch to the rack with a screwdriver and the

rack-mounting screws.

Figure 2-6. Mount the switch in an EIA standard 19-inch Rack

Note: For proper ventilation, allow about at least 4 inches (10 cm) of clearance on the

front and 3.4 inches (8 cm) on the back of the Switch. This is especially important for

enclosed rack installation.

Power On

Connect the power cord to the power socket on the rear panel of the switch.

Connect the other end of the power cord to an appropriate power outlet. The

internal power supply of the switch works with voltage range of AC in the

100-240VAC, frequency 50~60Hz.

Press the power On/Off switch to the On position and check the power indicator

on the front panel to see if power is properly supplied.