beautypg.com

Viewing or modifying qos record control settings, Configuring the vcx data server – H3C Technologies H3C Intelligent Management Center User Manual

Page 32

background image

23

{

Jitter Value Warning Threshold—Threshold of the QoS jitter warnings.

{

Jitter Value Severe Alarm Threshold—Threshold of the QoS jitter severe alarms.

{

Round Trip Delay Value Warning Threshold—Threshold of the QoS round trip delay value
warnings.

{

Round Trip Delay Value Severe Alarm Threshold—Threshold of the QoS round trip delay value
severe alarms.

{

Packet Loss Value Warning Threshold—Threshold of the QoS packet loss ratio warnings.

{

Packet Loss Value Severe Alarm Threshold—Threshold of the QoS packet loss ratio severe

alarms.

{

Computed MOS Value Warning Threshold—Threshold of the QoS MOS value warnings.

{

Computed MOS Value Severe Alarm Threshold—Threshold of the QoS MOS severe alarms.

{

End point Call History Depth—Number of calls used to calculate the average QoS statistics.

3.

Click OK.

Viewing or modifying QoS record control settings

1.

In the XML Accounting Server page, click the QoS Record Controls tab.

2.

View or modify the parameters of the QoS record control function:

{

File Path—Path that stores the CDR XML file. The root path is the VCX installation path.

{

Base Name—Name of the CDR XML file.

{

Type—Type of the CDR XML file. The type of the CDR XML file can be XML only.

{

Delimiter—Delimiter between fields in the CDR XML file.

{

Records Per File—Maximum number of CDR records in a single CDR XML file. The value range
is 1 to 65535.

{

Time to Close(s)—Maximum time of period during which the CDR XML file can be opened, in
seconds. The value range is 1 to 65535.

{

Time Stamp—Status of the time stamp. Options are Enabled and Disabled.

{

Execute Auto-Clean if the Latest is Bad Status—Whether or not the latest corrupted CDR file
deleting function is enabled. Options are Enabled and Disabled. After this function is enabled,

the system automatically deletes the latest corrupted CDR file at a specified interval.

{

Latest Bad Period(s)—Interval at which the latest corrupted CDR file is automatically deleted, in
seconds. The value range is 1 to 65535.

{

Execute Auto-Clean if the Latest is Dated Status—Whether or not the latest outdated CDR file
deleting function is enabled. Options are Enabled and Disabled. After this function is enabled,

the system automatically deletes the latest outdated CDR file at a specified interval.

{

Latest Stale Period(s)—Interval at which the latest outdated CDR file is automatically deleted, in
seconds. The value range is 1 to 65535.

3.

Click OK.

Configuring the VCX data server

In the Voice Device Information page, click VCX Data Server in the Component Name column. The VCX