Specified point load judgment (method 2 - type 1), Enforce – FEC DSP1500 (SAN3) User Manual
Page 90

PAGE 6-28
enFORCE
Operation Manual
♦
Specified Point Load Judgment (Method 2 – Type 1)
This Load Control press method allows judgment of a load (PS) at a given distance
[13: Standard Distance].
Type 1 Control is active if [22: Standard Distance] is set to a number other than 0.
Upon start of cycle, the press will operate until it achieves [13: Standard Load]. During
the press cycle, checks are performed for “1
ST
Judgment Zone”, 1
ST
Rate, 2
ND
Rate,
Load, Distance, 1
ST
Time and 2
ND
Time. If any of these values are compromised, the
press will stop and return as programmed. The Final Judgment will be based upon the
load value (PS) at [22: Standard Distance].
(See corresponding sections for Time, Rate, 1
ST
Zone and Speed explanations.)
If “1
ST
Judgment Zone” is not used, set [15: 1
ST
Load] to [10: CAL Load] and
[23: 1
ST
Distance] to a minimum of [21: High Distance].
Review Speed Section explanations and cautions when setting [15: 1
ST
Load],
[14: Speed Change Load], [24: Crossover Distance] and [20: Freerun
Distance].
If 1
ST
Rate or 2
ND
Rate are not used, set judgment windows wide open; low value
of 0 and maximum high value. Also, if 1
ST
H/L Check is not being used, set
[17: Threshold Load] to [10: CAL Load].
Load
Distance
High
Load Limit is set to
1.1 x [10] Calibration Load
[11] Low Load Limit
[13] Standard Load
[15] 1
ST
Load
[14] Speed Change Load
[17] Threshold Load
[20]
Low
Distance
[21]
High
Distance
2
ND
Rate
[41]
1
ST
Time
[42]
2
ND
Time
1
ST
Rate
[23]
1
ST
Distance
1ST Judgment Zone
Final Judgment Zone
[22]
Standard
Distance
Judgment Load (PS)
[12] High Load Limit
Chapter 6: System Operation
[18] Crossover Load