System Parameter 00, D-No. 08 – NEAR ORG/BANK1 signal is normally “BANK 1”.
To enable Output Banks 2 & 3, set Parameter 00-08 to ‘2’. (See Page 6-22)
If using the CYCLE OK signal, BANK 1 output is not available in Bank 1.
The BUSY signal is normally used to operate the brake. When changing Banks, the
meaning of the BUSY signal will change when a bank other than Bank 1 is selected.
(See Section 4.14 for Brake Operation)
BANK1 BANK0
OUT DATA Signal
Name
Description
OUT DATA0 BYPASS
Output when press is in BYPASS
OUT DATA1 ORG OK
Output after home position has been defined.
OUT DATA2 POS STOP
Output when the cylinder is stopped in home position.
OUT DATA3 BUSY
Output
while
operating.
OUT DATA4 READY
Output when the system is READY to operate.
OUT DATA5 ABNORMAL
Output when an Abnormal condition occurs.
OUT DATA6 ACCEPT
Output when the system has halted without failure.
OUT DATA7 REJECT
Output when the system has halted with failure.
OUT DATA8 ADVANCED
Output when the press has reached target load or distance.
OUT DATA9 TIMING
Output timing signal. Used when Par. 00, D-No. 0A is set.
OUT DATA10 CYCLE OK/BANK1
Output when the press reaches the distance set in Param.
00, D-No. 0A (1~9) / Output echo of Bank Select 1 Input.
OFF OFF
OUT DATA11 BANK0
Output echo of BANK Select 0 Input.
OUT DATA0
OUT DATA1
OUT DATA2
OUT DATA3 WORK SELECT 4
OUT DATA4 WORK SELECT 3
OUT DATA5 WORK SELECT 2
OUT DATA6 WORK SELECT 1
OUT DATA7 WORK SELECT 0
Output echo of selected Input.
OUT DATA8
OUT DATA9
OUT DATA10 BANK1
Output echo of BANK Select 1 Input.
OFF ON
OUT DATA11 BANK0
Output echo of BANK Select 0 Input.
OUT DATA0 LOAD_LOW
Output on a Low Load Reject.
OUT DATA1 LOAD_HIGH
Output on a High Load Reject.
OUT DATA2 Rt2_LOW
Output on a Low Rate 2 Reject.
OUT DATA3 Rt2_HIGH
Output on a High Rate 2 Reject.
OUT DATA4 Rt1_LOW
Output on a Low Rate 1 Reject or 1
ST
zone High Abnormal
OUT DATA5 Rt1_HIGH
Output on a High Rate 1 Reject or 1
ST
zone Low Abnormal.
OUT DATA6 DIS_LOW
Output on a Low Distance Reject
OUT DATA7 DIS_HIGH
Output on a High Distance Reject.
OUT DATA8
OUT DATA9
OUT DATA10 BANK1
Output echo of Bank Select 1 Input.
ON OFF
OUT DATA11 BANK0
Output echo of Bank Select 0 Input.
OUT DATA0
OUT DATA1
OUT DATA2
OUT DATA3
OUT DATA4
OUT DATA5
OUT DATA6
OUT DATA7
OUT DATA8
OUT DATA9
OUT DATA10 BANK1
Output echo of Bank Select 1 Input
ON ON
OUT DATA11 BANK0
Output echo of Bank Select 0 Input.