Press result display mode – FEC DSP1500 (SAN3) User Manual
Page 73

PAGE 6-11
enFORCE
Operation Manual
6.3.5 Press Result Display Mode
The following is displayed on the screen in the Press Result Display Mode.
The [D-NO] changes by pressing the [↑] and [↓] buttons.
D-NO DATA UNIT
_0
Peak Load Value(Judgment Load Value) KN
_1
Final Distance Value
mm
_2
1
ST Load Rate Value
KN/mm
_3
2
ND Load Rate Value
KN/mm
_4
1
ST Field Operating Time
Sec
_5
Final Field Operating Time
Sec
_6
Cycle Time
Sec
_7
Operating Mode Number
-0
Operating Method Number
-1
Step
-2
(Monitor)not used
-3
Self Check ON: performed OFF: not performed
-4
Inversion Plug ON: inverted OFF: not inverted
-5
Cause of press stop
0: Reset/No Data/After hand operated,
1: Abnormal 2: BYPASS signal 3: STOP signal
4: REJECT 5: ACCEPT(normal)
-6
Load Judgment Ld H/L
-7
Distance Judgment dS H/L
-8
Load Rate Judgment rt H / L(1
ST
, 1
ST
ZONE) H / L(2
ND
)
-9
Time Judgment Γi H/L(1
ST
)
H/L(FNL)
=0
1
ST
Load Rate Area Increment Load
KN
=1
2
ND
Load Rate Area Increment Load
KN
=2
1
ST
Final Load
KN
=3
1
ST
Peak Load
KN
=4
Final Load Value
KN
=5
Distance at Peak Load (judge load) mm
「
D-NO」 「DATA」
Peak load value
Final Distance value
1ST Load Rate
Distance at Peak Load
Chapter 6: System Operation
D-NO
:
left side figure
0
1
2
5
[↑] / [↓]
buttons