beautypg.com

Press result display mode – FEC DSP1500 (SAN3) User Manual

Page 73

background image

PAGE 6-11

enFORCE

Operation Manual

6.3.5 Press Result Display Mode

The following is displayed on the screen in the Press Result Display Mode.
The [D-NO] changes by pressing the [↑] and [↓] buttons.

D-NO DATA UNIT

_0

Peak Load Value(Judgment Load Value) KN

_1

Final Distance Value

mm

_2

ST Load Rate Value

KN/mm

_3

ND Load Rate Value

KN/mm

_4

ST Field Operating Time

Sec

_5

Final Field Operating Time

Sec

_6

Cycle Time

Sec

_7

Operating Mode Number

-0

Operating Method Number

-1

Step

-2

(Monitor)not used

-3

Self Check ON: performed OFF: not performed

-4

Inversion Plug ON: inverted OFF: not inverted

-5

Cause of press stop

0: Reset/No Data/After hand operated,

1: Abnormal 2: BYPASS signal 3: STOP signal

4: REJECT 5: ACCEPT(normal)

-6

Load Judgment Ld H/L

-7

Distance Judgment dS H/L

-8

Load Rate Judgment rt H / L(1

ST

, 1

ST

ZONE) H / L(2

ND

)

-9

Time Judgment Γi H/L(1

ST

H/L(FNL)

=0

1

ST

Load Rate Area Increment Load

KN

=1

2

ND

Load Rate Area Increment Load

KN

=2

1

ST

Final Load

KN

=3

1

ST

Peak Load

KN

=4

Final Load Value

KN

=5

Distance at Peak Load (judge load) mm


D-NO」 「DATA


Peak load value



Final Distance value



1ST Load Rate






Distance at Peak Load

Chapter 6: System Operation

D-NO

left side figure

[↑] / [↓]

buttons