Load control (method 0), Enforce, Operation methods – FEC DSP1500 (SAN3) User Manual
Page 88

PAGE 6-26
enFORCE
Operation Manual
♦
Load Control (Method 0)
Upon start of cycle, the press will operate until it achieves [13: Standard Load]. During
the press cycle, checks are performed for “1
ST
Judgment Zone”, 1
ST
Rate, 2
ND
Rate,
Load, Distance, 1
ST
Time and 2
ND
Time. If any of these values are compromised, the
press will stop and return as programmed.
(See corresponding sections for Time, Rate, 1
ST
Zone and Speed explanations.)
If “1
ST
Judgment Zone” is not used, set [15: 1
ST
Load] to [10: CAL Load] and
[23: 1
ST
Distance] to a minimum of [21: High Distance].
Review Speed Section explanations and cautions when setting [15: 1
ST
Load],
[14: Speed Change Load], [24: Crossover Distance] and [20: Freerun
Distance].
If 1
ST
Rate or 2
ND
Rate are not used, set judgment windows wide open; low value
of 0 and maximum high value. Also, if 1
ST
H/L Check is not being used, set
[17: Threshold Load] to [10: CAL Load].
Chapter 6: System Operation
Load
Distance
[12]
High
Load Limit
[13] Standard Load
[11] Low Load Limit
[18] Crossover Load
[15] 1
ST
Load
[14] Speed Change Load
[17] Threshold Load
[20]
Low
Distance
[21]
High
Distance
2
ND
Rate
[41]
1
ST
Time
[42]
2
ND
Time
1
ST
Rate
1
ST
Judgment Zone
Final Judgment Zone
[23]
1
ST
Distance
Operation Methods