PAGE 6-22
enFORCE
Operation Manual
¾
Data number
08
Near Origin Sensor Availability/Bank Select Enable
□ □ □ □
0: No Near Origin sensor (Default)
1: Near Origin sensor attached (on presses 10 ton and larger)
2: Bank Select enable (enable output signal banks 2 & 3)
0: Enable Distance High Limit Stop (Default)
1: Disable Distance High Limit Stop
0: 0.1mm distance sampling
1: 0.01mm distance sampling
2: 0.005mm distance sampling
Operation of setting bank change
OUT DATA Banks can be selected by PIN number 9: NEAR ORIGIN/BANK 1 or
11: BANK 0 signals of the PLC I/O Connector.
See Section 4.7 “External Control Signal Connection” for further details.
Allow a minimum of 20ms to read the Bank 0 and Bank 1 Echo Outputs
when using the Data Bank Select signals
¾
Data number
09
Home Position Search Time Out
It sets the time limit of the home position search operation.
*If the operation has not finished within the time limit an abnormal will occur.
¾
Data number
0A
Distance Decimal / Deadman / Data Speed / Special Setting
□ □ □ □
Distance decimal
0: No decimal, 1: X.X, 2: X.XX
*This is factory preset. Do not change unless necessary.
You need to re-input the data if changing the distance
decimal because the decimal point of all the distance-
related data will be changed.
0: Normal Operation (Deadman Mode Disabled)
1: Home Positioning function is in Deadman Mode
2: Automatic Return function is in Deadman Mode
3: Home Positioning
&
Automatic Return is in Deadman Mode
0: RS-485
9600bps RS-232C
9600bps
1:
19200bps 9600bps
2: 38400bps 9600bps
3: 9600bps 19200bps
4:
19200bps 19200bps
5:
38400bps 19200bps
6:
9600bps 38400bps
7:
19200bps 38400bps
8:
38400bps 38400bps
*Power must be cycled for these changes to take effect.
0: No output function(rate supervise performed)
1: Sets Pin #34 option output ON 1mm before the standard distance
9: Sets Pin #34 option output ON 9mm before the standard distance
*Using settings 1-9 also enables the Timing signal (Pin #33).
Distance data is set up in Param. 1-32, D-No. 30, 31, 32 and 33.
30: Advance ON Distance 31: Advance OFF Distance
32: Return ON Distance
33: Return OFF Distance
Chapter 6: System Operation