Rs232c output format – FEC DSP1500 (SAN3) User Manual
Page 66

PAGE 6-4
enFORCE
Operation Manual
6.1.2 RS-232C Output Data
Result data is output every time the operation is finished.
The result output is possible for each unit that has a SAN –DP2S/SP4S installed.
Use SAN –IF unit if you want to output multiple results.
Result Output Data
Data Length: 78 bytes fixed (78 letters)
Normal data format
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
COUNT Number
Press
Number
PARM
Number
30H 30H 30H 31H 20H 20H 20H 20H 30H 31H 20H 20H 20H 31H 20H 20H
0 0 0 1 0 1 1
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
PEAK LOAD
Judg
ment
FINAL DISTANCE
Judg
ment
31H 32H 2EH 33H 34H 20H 20H 20H 31H 32H 2EH 33H 34H 20H 20H 20H
1 2 . 3 4 1 2 . 3 4
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
FINAL LOAD
1ST RATE
Judg
ment
31H 32H 2EH 33H 34H 20H 20H 20H 30H 2EH 31H 32H 33H 20H 20H 20H
1 2 . 3 4 0 . 1 2 3
49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64
2ND RATE
Judg
ment
1ST TIME
Judg
ment
30H 2EH 31H 32H 33H 20H 20H 20H 20H 31H 30H 2EH 30H 20H 20H 20H
0 . 1 2 3 1 0 . 0
65 66 67 68 69 70 71 72 73 74 75 76 77 78
2ND TIME
Judg
ment
Judg
ment
CR
LF
20H 20H 32H 2EH 30H 20H 20H 20H 4FH 20H 20H 20H 0DH 0AH
2 . 0 O
Overall Judgment
"O":4FH ACCEPT
"X":58H REJECT
"0001 01 1 12.34 12.34 12.34 0.123 0.123 10.0 2.0 O" +CR+LF
Judgment letters displayed beside PEAK LOAD value
H: Exceeded High Value
L: Below Low Value
A:
Abnormal
S: STOP
B: BYPASS (Press Unit Off)
Judgment letter displayed beside DISTANCE, RATE and TIME value
H: Exceeded high value
L: Below low value
COUNT Number: ‘0001’ is displayed after powering ON. 1 is added after each cycle.
Chapter 6: System Operation