70
AP
PENDIX
4. SPECIFICATIONS
Note that product appearance and specifications are subject to change without prior notice.
Hard disk capacity
Upgradeable to two (2), maximum 300 GB hard disks
Television system
NTSC/PAL color signal standard (Switchable)
Picture resolution
NTSC: 720 x 480 pixels (Super+/Super/High/Standard)
PAL:
720 x 576 pixels (Super+/Super/High/Standard)
Compression
Video
MPEG2
Audio
MPEG1 Audio Layer2
Picture quality
4 levels (Super+/Super/High/Standard)
Recording type
Frame
Recording speed
NTSC: 30 fps or PAL: 25 fps
Screen
Single screen/Quad screen
Playback
Playback, Still, Search, Cue, Review, Slow/reverse, Frame advance/reverse
Recording
Normal recording
Records on quad screen
Timer recording
Records on quad screen
Alarm recording
Records on quad screen
Search mode
Time/date search
Search by time and date
Alarm search
Search by alarm event list
Menu language
English/French/Spanish
Clock settings
Month/Day/Year/Hours/Minutes/Seconds
Miscellaneous functions
Motion sensor, Security lock (with password function)
Video input terminal
1V (p-p), 75 Ohm unbalanced, 4 BNC connectors
Video output terminal
1V (p-p), 75 Ohm unbalanced, 4 BNC connectors
Video monitor out terminal
1V (p-p), 75 Ohm unbalanced, 1 BNC connector
Audio input terminal
-8 dbs, 47 k Ohm unbalanced (4 RCA pin jacks)
Audio output terminal
-8 dbs, 600 Ohm unbalanced (1 RCA pin jack)
Microphone input terminal
-60 dbs, 10 k Ohm unbalanced (3.5 mm mono jack)
LAN terminal
100BASE-TX (RJ-45)
USB port
For external storage unit (CompactFlash card reader, CD-R/RW drive)
Control
connector
(Push lock)
RS-485 terminal
3 terminals (A, B, GND)
Remote control terminal
Resistance ladder
Clock adjust input terminal
Normal open, Low level active
Clock adjust output terminal
Normal 5 V, Low level active
Series rec input terminal
Normal open, Low level active
Non rec output/
Series rec output terminal
Normal 5 V, Low level active
Alarm input terminal
Normal open, Low level active (4 channels)
Alarm reset terminal
Normal open, Low level active
Alarm output terminal
Normal 5 V, Low level active
Warning output terminal
Open collector (500 mA), Low level active
Full out warning terminal
Open collector (50 mA), Low level active
Power
120 – 240 V AC, 50/60 Hz
Current consumption
480 mA
Operating temperature
5
°C to 40°C (41°F to 104°F)
Operating humidity
10% to 80%
Dimensions
210 (W) x 96 (H) x 391.5 (D) mm
Weight
3.7 kg
e00_VDH_M814.book Page 70 Thursday, October 28, 2004 9:59 AM