beautypg.com

Control terminal specifications, System controller connections, Appendix – Sanyo DSR-M814 User Manual

Page 67: Connecting cables to the control terminals

background image

66

AP
PENDIX

APPENDIX

1. CONTROL TERMINAL SPECIFICATIONS

*1 Used for twisted-pair cable connection.
*2 Outputs SERIES REC OUT when OVER WRITE in REC MODE SET is

“OFF”, and SERIES REC is “-1M”, “-2M”, or “-3M”. Outputs NON REC
OUT when SERIES REC is “OFF”.

*3 The following warnings are output:

z

Hard disk drive error

z

Fan error

z

Recording error

z

No input signal when VIDEO LOSS is ON.

Connecting cables to the control terminals

(1) Push in the lock pin with a flat-blade screwdriver.

(2) Insert the cable.

(3) Pull out the lock pin with a flat-blade screwdriver. The

cable is now secured in place.

The connections for a system controller are shown below.
Insert a twisted-pair cable (sold separately) into the
RS-485A, RS-485B and C (ground) terminals on the rear
panel. Connect the RS-485A and RS-485B output to signal
A and signal B respectively of the system controller.

z

Twisted-pair cable
Reduces signal interference caused by noise from other
cables.

z

For information about the system controller, contact your
local dealer.

Terminal

No.

Name

Signal

Function

1

RS-485A

RS-485

To RS-485 terminal signal
A*

1

2

RS-485B

RS-485

To RS-485 terminal signal
B*

1

3

C

Common

4

REMOTE

Resistance ladder
connection

Remote Control terminal

5

C

Common

6

CLOCK ADJ IN

Normal open,
Low level active

Input for clock setting

7

CLOCK ADJ
OUT

Normal resistance
5V DC/57k

Ω,

Low level active

Output for clock setting

8

C

Common

9

SERIES REC
IN

Normal open,
Low level active

Input terminal used when
recording with multiple
digital video recorders
connected.

10

NON REC
OUT/SERIES
REC OUT

Normal resistance
5V DC/57k

Ω,

Low level active

Output terminal used
when recording with
multiple digital video
recorders connected.*

2

11

ALARM IN 1

Normal open,
Low level active

Alarm input for channel 1

12

ALARM IN 2

Normal open,
Low level active

Alarm input for channel 2

13

ALARM IN 3

Normal open,
Low level active

Alarm input for channel 3

14

ALARM IN 4

Normal open,
Low level active

Alarm input for channel 4

15

ALARM
RESET

Normal open,
Low level active

Alarm reset input

16

ALARM OUT

Normal resistance
5V DC/57k

Ω,

Low level active

ALARM OUT

17

C

Common

18

WARNING
OUT

Open collector
(500 mA),
Low level active

Warning output*3

19

DISK FULL
OUT

Open collector
(500 mA),
Low level active

Recording area full
warning

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

System controller connections

Cable

Flat-blade screwdriver

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

RS-485

A B C

Twisted-pair cable

Ground

To signal B

To signal A

RS-485

terminal

System controller (sold separately)

e00_VDH_M814.book Page 66 Thursday, October 28, 2004 9:59 AM